130 Ebony Boulevard - Swimming Pool

130 Ebony Boulevard Sherwood Park AB T8H0L2 · Aquatic Facility

28 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 120 on the lab report. Remediate and resample.
  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC count was 190 on the lab report. Remediate and resample.
  4. Monitoring Inspection

    0 infractions

  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from water sample collected September 16 2025 indicate a Heterotrophic plate Count of 110 CFU/mL.Resample requested.
  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from water sample collected August 7, 2025 indicate a Heterotrophic plate Count of 880 CFU/mL.Resample requested.
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken July 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.Results from sample Taken July 22 showed a HPC of 320 CFU/mL.Operator to close pool until inspection occurs and satisfactory water sample result is received.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.
  11. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken July 10, 2025 showed a HPC of 390 CFU/mL.Operator requested to treat and resample.Results from sample taken July 15, 2025 showed a HPC of 190 CFU/mL.Operator requested to treat and resample.
  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 1570 CFU/mL.Operator requested to treat and resample.
  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Results from sample taken June 10, 2025 showed a HPC of 730 CFU/mL.
  14. Risk Management Inspection

    0 infractions

  15. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Free Available Chlorine measured 0.12 ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Automated controller indicated pH of pool was 7.2, while manual readings found the pH to be 7.6
  16. Risk Management Inspection

    0 infractions

  17. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 140- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The pool will remain closed until a satisfactory sample will be received.
  18. Risk Management Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliforms present
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The will remain closed until a satisfactory sample will be received.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  19. Risk Management Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced. The will remain closed until a satisfactory sample will be received.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  20. Risk Management Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliform present
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC present- The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  21. Monitoring Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Collection Date: 2024-08-15** Heterotrophic Plate Count: 1740 CFU/mL - The operator will shock chlorinate the pool, with pool closed to the public during the procedure, then re-sample when the water chemistry is balanced.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The weir door was missing at the swimming pool skimmer inlet adjacent on the southwest side of the swimming pool.- Replace the weir door to allow for proper skimmer function.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Record log of water chemistry testing results and readings did not have the date of testing recorded. - Ensure to fill out the date section of record log for accurate record keeping.
  22. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • CYA 57
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Manual chemistry records are not maintained every day as per the requirements. Ensure adequate records are maintained as work/readings is completed.
  23. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • High HPC count (700)
  24. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • High HPC count (740).
  25. Risk Management Inspection

    0 infractions

  26. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • OR readingpH 7.7
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • *Alarm light was illuminated on the controller and a low ORP (around 276 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.
  27. Risk Management Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC 0.22
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • *Alarm light was illuminated on the controller and a low ORP (around 276 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • *Debris were observed in the pool basin. Remove and vacuum the basin to remove debris and dirt.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Anti-entrapment plan for the pool not in place. A plan with pool information was submitted; however, the plan does not appear to be match the pool's mechanical drawing information.
  28. Initial Inspection

    3 infractions

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • *No flow was observed at the flow meter level.*Alarm light was illuminated on the controller and a low ORP (around 230 mV). Investigate and make adjustments as required to ensure chlorine generation system in good working order.*Cavitation like noise was observed for the pump.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • *Large debris had blown into the pool basin. Remove and vacuum the basin to remove debris and dirt.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • *Anti-entrapment plan for the pool not in place. A plan with pool information was submitted; however, the plan does not appear to be match the pool's mechanical drawing information.