Calgary Aesthetics
825 12 Avenue SW Calgary AB T2R 0J2 · Personal Services
2 inspections
- Initial Inspection
0 infractions
- Demand Inspection
4 infractions
- 20. Is reusable equipment disinfected properly?
- The two bottles of CS20 available had expired.Obtain high level disinfectant within the expiry date.
- 20. Is reusable equipment disinfected properly?
- Improper disinfectant test strips were available for use.Obtain the correct corresponding test strips to go along with the high level disinfectant used.
- 20. Is reusable equipment disinfected properly?
- Reusable tools from eyelash extensions were being disinfected in CS20 for 10 minutes.If using CS20, tools must be disinfected for 20 minutes in the CS20 solution.
- 20. Is reusable equipment disinfected properly?
- Reusable eyelash extension tools were not being dried before being disinfected.Proper disinfectant procedure for reusable eyelash extension tools is:- Wash with detergent/soap and water- Rinse with fresh water- Completely dry (either air dry or towel dry with a clean towel or clean paper towel)- Disinfect. If using CS20, fully submerge tools for 20 minutes.- Rinse with fresh water- Dry
- 20. Is reusable equipment disinfected properly?