Skip to content
Loading map…

Days Inn by Windham - Whirlpool

4710 58 Street Redwater AB T0A 2W0 · Aquatic Facility

5 inspections

  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The bacteria water sample 24EN-345E00695 has an HPC of 1640 CFU/100 mL. This could indicate a failure of the disinfection system. Please ensure that there is at least 1 ppm Free Chlorine, a pH of between 6.8 and 7.6 and a Total Alkalinity between 60 and 180 mg/L in the whirlpool water.
  2. Risk Management Inspection

    0 infractions

  3. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity is higher than 180 ppm. Ensure total alkalinity is between 60 ppm to 180 ppm range at all times.
  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions