  1. Risk Management Inspection

    2 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedure for antiseptic use was available.
    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • Unacceptable antiseptic product was used for skin preparation: no DIN or NPN was available.
  2. Risk Management Inspection

    3 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for skin cleansing prior to services, antiseptic use, accidental cuts and reprocessing sink decontamination were available.
    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • Unacceptable antiseptic product was used for skin preparation: no DIN or NPN was available.
    • 31. Are sinks accessible and used appropriately for the personal services provided?
      • Reprocessing sink located in the service room was also used for hand washing, and no written procedure for sink decontamination prior to tools reprocessing was available.
  3. Monitoring Inspection

    11 infractions

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • No written procedures for skin cleansing prior to services, antiseptic use, accidental cuts and reprocessing sink decontamination were available.
    • 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
      • Unacceptable antiseptic product was used for skin preparation: no DIN or NPN was available.
    • 11. Is post-service care provided by personal service workers following any personal service or accident where a client's skin or mucous membrane is cut or punctured during a personal service, or when energy-emitting equipment is used?
      • Post treatment care instructions were not available during the inspection.
    • 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
      • Sterility assurance documentation for sterile equipment was not retained with the clients' records. Discussed. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
    • 20. Is reusable equipment disinfected properly?
      • The product used for surface disinfection (alcohol) was not an approved disinfectant (no DIN). Approved surface disinfectant (Preempt wipes) was available and will be used instead.
    • 20. Is reusable equipment disinfected properly?
      • No soaking tray was available for disinfection of the tools. The semi-critical tools must be disinfected by soaking in a high-level disinfectant.
    • 20. Is reusable equipment disinfected properly?
      • No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
    • 20. Is reusable equipment disinfected properly?
      • No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
    • 20. Is reusable equipment disinfected properly?
      • No high-level disinfectant has been used or available for tools disinfection. Approved high-level disinfectant is required.
    • 26. Are cosmetic products appropriate for their intended use and being handled properly?
      • Some cosmetic products did not have appropriate labels. Ensure that all cosmetic products have appropriate labels.
    • 31. Are sinks accessible and used appropriately for the personal services provided?
      • Reprocessing sink located in the service room was also used for hand washing, and no written procedure for sink decontamination prior to tools reprocessing was available.