Evershine Nails
4103 - 230 Eversyde Boulevard SW Calgary AB T2Y 0J4 · Personal Services
6 inspections
- Demand Inspection
4 infractions
- 06. Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?
- Operator is unable to identify non-critical, semi-critical and critical classes of equipment. Operator states nail bits are sprayed and wiped with alcohol.Nail bits are a semi-critical item and needs to be disinfected in CS-20
- 13. Is single-use or uncleanable equipment being used as intended (Critical)?
- Toe separators that are porous and uncleanable observed to be reused. Nail residue and dust observed in basket where items have been stored. Toe separators observed to have nail polish on some. Items have been discarded, please note retrieving items from the garbage can lead to enforcement.
- 17. Is reusable equipment cleaned properly (Critical)?
- Operator states drill bits are kept at the stations, sprayed with alcohol and reused. Metal drill bits for nail grinding are classified as semi-critical items and must be disinfected using a high-level disinfectant.
- 20. Is reusable equipment disinfected properly?
- Repeat Violation- PHI will send you High level disinfectant log forms to keep tract and document.Previous Violation1. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.March 25, 2025: Repeat violation. Ensure a test log is maintained.
- 06. Do operators and personal services workers comply with the Personal Services Regulation and Standards and do they have the skills and knowledge to perform their duties in a safe and sanitary manner?
- Monitoring Inspection
2 infractions
- 20. Is reusable equipment disinfected properly?
- 1. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.March 25, 2025: Repeat violation. Ensure a test log is maintained.
- 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
- The silver wax trolley had an accumulation of dust and debris.Thoroughly clean this trolley and maintain it in a sanitary manner.
- 20. Is reusable equipment disinfected properly?
- Risk Management Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- 1. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.
- 20. Is reusable equipment disinfected properly?
- Monitoring Inspection
2 infractions
- 20. Is reusable equipment disinfected properly?
- 1. CS20 high level disinfectant expired on August 10, 2024. *This is a repeated infraction.* - It appears that CS20 disinfectant is not being used. - Obtain a new disinfectant. - A high level disinfectant must be used on all semi-critical tools. 2. Found alcohol on site in a soaking container. - Alcohol is not an approved disinfectant. 3. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.4. Food paddles do not fit into CS20 soaking container, because it's too small. - Food paddlers must be fully immersed in CS20 disinfect for 20 minutes. 5. CS20 disinfectant is not being rinsed off after soaking. - Rinse tools with water after 20 minutes soaking time.6. PreEMPT RTU disinfectant is old and expiry date could not be read. Using Mr. Clean for cleaning step. - Obtain new PreEMPT RTU disinfectant.
- 29. Is the facility properly constructed and maintained to allow for the safe and sanitary provision of personal services (Non-Critical)?
- Surface on waxing chair's handrests was damaged. -Repair the surface so it is smooth and easy to clean.
- 20. Is reusable equipment disinfected properly?
- Risk Management Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- 1. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.
- 20. Is reusable equipment disinfected properly?
- Monitoring Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- 1. CS20 high level disinfectant was expired. - Replace the disinfectant immediately. 2. CS20 high level disinfectant is not being tested daily when reused for more than a day. Tests must be recorded. - Test and record CS20 disinfectant concentration daily.
- 20. Is reusable equipment disinfected properly?