Hampton Inn & Suites by Hilton St. Albert - Swimming Pool
585 Mistatim Way NW Edmonton AB T6V0M8 · Aquatic Facility
12 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Monitoring Inspection
3 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The total alkalinity of the swimming pool was tested to be at 22ppm during the time of inspection.Please ensure that the total alkalinity is maintained between 60-180ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated controller readings are inconsistent with manual testing, the automated reading for pH were 7.22 and the manual testing for pH was 6.96. Please ensure that the automated reading for the controller is more consistent with manual testing. Consider recalibration or cleaning the sensors.
- 16. Are proper testing, monitoring, and other records being properly maintained?
- Inconsistencies in daily record keeping observed during the inspection, some chemical water parameters were not consistently being tested every day.Please ensure that the daily testing log sheet is filled out in its entirety every day of operation.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- The main drain covers have expired.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- An updated anti-entrapment plan is required to be provided to this office.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- One of the two lectranator's were in disrepair. Parts are on order. Please provide this office with further details as to repairs required and proposed timeframe for completion of repairs.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow meter was not operational. Repair/replace.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 2023-11-29 [Accession: WE-23-0128285] was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample collected on 2023-12-06 [Accession #: WE-23-0131011] was unsatisfactory: HPC: 130 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on 2023-11-29 [Accession: WE-23-0128285] was unsatisfactory: HPC >57000 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?