Home 2 Suites by Hilton - Edmonton South - Whirlpool

1140 103 A Street SW Edmonton AB T5J 2Z1 · Aquatic Facility

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.0, and the manual reading for pH 7.66. Please address.
  3. Risk Management Inspection

    0 infractions

  4. Monitoring Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 14.16 gpm/sq ft based on a filtration area of 7.06 sq ft and flow rate 100 gpm. Note: flow rate should not exceed 88 gpm to provide proper filtration rate.
  5. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.3 and the manual pH reading 7.6.
  6. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 24EN-263E00797 submitted on September 19, 2024, was unsatisfactory: Pseudomonas aeruginosa isolated and HPC over 57000. The previous sample was satisfactory.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 24EN-263E00797 submitted on September 19, 2024, was unsatisfactory: Pseudomonas aeruginosa isolated and HPC over 57000. The previous sample was satisfactory.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.3 and the manual pH reading 7.6.
  7. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-24-0011066 submitted on February 2, 2024, was unsatisfactory: Pseudomonas aeruginosa isolated.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.3 and the manual pH reading 7.6.
  8. Risk Management Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.3 and the manual pH reading 7.6.
  9. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • There was a discrepancy between the automated controller reading for pH 7.3 and the manual pH reading 7.6.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration for the filtration system was 13.46 gpm/sq ft based on a filtration area of 7.06 sq ft, which exceeded the maximum allowed filtration rate of 12.5 gpm/ft2. Note: flow rate should not exceed 88 gpm to provide proper filtration rate.