Skip to content
Loading map…

Olds Centennial Park Splashpark

5037 53 Street Olds AB · Aquatic Facility

6 inspections

  1. Monitoring Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Tested readings:Free available chlorine -1.94 ppmpH - 7.47Temperature - 22.4COperator increased chlorine pump to meet 2.0 ppm requirement.
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • 1. Routine water sample result: HPC – 110 CFU/mlClose the park from public use immediately. Shock chlorinate the park. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 2.0ppm. The park can then be re-opened to the public.Resample on your regular sampling day
  5. Monitoring Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 160Notified operator, Michelle. Water chemistry has been balanced. Chlorine readings sitting around a 1.5-2ppm. Acid set point increased to pH of 7.5 as they were going through a lot of acid. The park features were shut off for a few days last week due to rain and cooler weather. Operator backwashed and increased chlorine to 5 ppm today. ORP was at 775. She will keep chlorine higher this week as the weather is supposed to be warm.