Park Place II - Pool
570 Park Ave West, Chatham ON N7M 1X2 · Outdoor class B pool
9 inspections
- Follow-up
0 infractions
- Required
2 infractions
- Operator demonstrates satisfactory attendance at the facility to ensure safe operation. s.26.5
- Operator must demonstrate satisfactory attendance at the facility and must regularly record the results of inspections of safety-related equipment present
- Manual testing conducted 1/2 hour before opening and every 2 hours during the daily use period for pools without automatic sensing devices (pH, FAC, total chlorine or Br, total alkalinity, water clarity); s.7(12)
- Operator demonstrates satisfactory attendance at the facility to ensure safe operation. s.26.5
- Follow-up
0 infractions
- Required
3 infractions
- All circulation equipment and chemical feeders operate continuously s.6(3)(d)
- Ensure there is continuous operation of all equipment and chemical feeders
- Daily records completed and signed s.8
- Complete and sign records daily
- Record any emergencies, rescues or breakdowns of equipment
- Record Cl (free and total) residual 1/2 hour before opening & every 4 hours while pool is open
- Record pH 1/2 hour before opening & every 4 hours while pool is open
- Record total alkalinity 1/2 hour before opening and every 4 hours while pool is open
- Record water clarity 1/2 hour before opening and every 4 hours while pool is open
- Record reading of the make-up water meter
- Record time of day for testing of emergency telephone
- Record time of day for testing of ground fault detector
- Record total number of bathers admitted to pool each day
- Record the type and amount of any chemicals added manually
- Records retained for one year s.9
- All circulation equipment and chemical feeders operate continuously s.6(3)(d)
- Required
4 infractions
- Exposed piping within pool enclosure is properly colour-coded s.6(6)(p)
- Ensure exposed piping is painted or colour-coded with bands at least 25mm wide, at intervals no greater than 1.2 m (chlorine - yellow, potable water - green)
- pH is within range of 7.2 to 7.8 s.7(8)(b)
- Maintain pH between 7.2 to 7.8
- Manual testing conducted 1/2 hour before opening and every 4 hours during the daily use period for pools with automatic sensing devices (pH, FAC, total chlorine or Br, total alkalinity, water clarity); s.7(12)
- Ensure manual testing is conducted every 4 hours during the daily use period
- Daily records completed and signed s.8
- Complete and sign records daily
- Record Cl (free and total) residual 1/2 hour before opening & every 4 hours while pool is open
- Record pH 1/2 hour before opening & every 4 hours while pool is open
- Record total alkalinity 1/2 hour before opening and every 4 hours while pool is open
- Record water clarity 1/2 hour before opening and every 4 hours while pool is open
- Record time of day for testing of emergency telephone
- Record the type and amount of any chemicals added manually
- Exposed piping within pool enclosure is properly colour-coded s.6(6)(p)
- Required
2 infractions
- Manual testing conducted 1/2 hour before opening and every 4 hours during the daily use period for pools with automatic sensing devices (pH, FAC, total chlorine or Br, total alkalinity, water clarity); s.7(12)
- Ensure manual testing is conducted every 4 hours during the daily use period
- Daily records completed and signed s.8
- Complete and sign records daily
- Record any emergencies, rescues or breakdowns of equipment
- Record Cl (free and total) residual 1/2 hour before opening & every 4 hours while pool is open
- Record pH 1/2 hour before opening & every 4 hours while pool is open
- Record total alkalinity 1/2 hour before opening and every 4 hours while pool is open
- Record water clarity 1/2 hour before opening and every 4 hours while pool is open
- Record time of day for testing of emergency telephone
- Record the type and amount of any chemicals added manually
- Manual testing conducted 1/2 hour before opening and every 4 hours during the daily use period for pools with automatic sensing devices (pH, FAC, total chlorine or Br, total alkalinity, water clarity); s.7(12)
- Required
4 infractions
- Exposed piping within pool enclosure is properly colour-coded s.6(6)(p)
- Ensure exposed piping is painted or colour-coded with bands at least 25mm wide, at intervals no greater than 1.2 m (chlorine - yellow, potable water - green)
- Total alkalinity within the range of 80 mg/L (80ppm) and 120 mg/L (120ppm) s.7(8)(a)
- Maintain total alkalinity within the range of 80 mg/L (80ppm) and 120 mg/L (120ppm)
- Pool Rules notices displayed with complete information s.19(1)
- Ensure at least two "Pool Rules" notices are displayed
- Admission Standards "Important Notice" posted at entrance and two other locations within pool enclosure
- Ensure the admission standards "Important Notice" is posted at the pool entrance
- Ensure the admission standards "Important Notice" is posted in two locations in the pool
- Exposed piping within pool enclosure is properly colour-coded s.6(6)(p)
- Required
0 infractions
- Required
1 infraction
- Depth markings present in appropriate locations s.19(6)
- Ensure depth markings are maintained and clearly visible
- Ensure figures are marked not less than 100 mm high
- Ensure markings are indicated at the appropriate locations
- Provide markings that indicate "SHALLOW AREA"
- Provide markings that indicate breaks between gentle and steep bottom slopes
- Provide markings that indicate deep points
- Provide markings that indicate shallow points
- Depth markings present in appropriate locations s.19(6)