  1. Required

    0 infractions

  2. Required

    1 infraction

    • Did operator properly disinfect equipment and surfaces?
      • Disinfect reusable equipment after use on a client to prevent disease transmission.
      • Disinfect reusable equipment with appropriate disinfectant required for the equipment.
      • Fully immerse reusable equipment in the disinfectant.
      • Low-level disinfectant: Mix 2 ml (½ tsp) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Prepare a new bleach and water solution daily.
      • Low-level disinfect equipment and surfaces that do not directly contact the client, or contact only hair or intact skin (e.g., combs, reusable handles/holders for blades, magnifying glasses, equipment covered with single use disposable plastic liner, client chairs, client beds).
      • Clean and low-level disinfect low-risk environmental surfaces (e.g., manicure/waxing tables, chairs, or beds that are covered with a single-use towel/ cover) at the end of the day or when visibly soiled.
      • Clean and low-level disinfect high-risk environmental surfaces (e.g., tattoo tables, beds, or chairs where invasive procedures are carried out) after every use.
      • Intermediate-level disinfectant: Mix 20 ml (4 tsp) of 5.25% bleach with 500 ml (2 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 5 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
      • Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
      • Pedicure basin with single use disposable liner: Clean the basin with detergent, water and scrub brush after every use. Clean and low level disinfect at the end of the day. If the liner tears or breaks while in use, clean and intermediate level disinfect the basin immediately after use. If a magnetic jet cover is used in the spa water, it must be cleaned and intermediate level disinfected after every use. (Show More)
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.