Tatyana's Laser Hair Removal
314 Reunion Heath NW Airdrie AB T4B 0M5 · Personal Services
3 inspections
- Risk Management Inspection
0 infractions
- Monitoring Inspection
1 infraction
- 20. Is reusable equipment disinfected properly?
- Operator indicated that intermediate-level disinfectant (Cavicide 3) was being used to disinfect pedicure tools that are deemed to require high-level disinfection. The only available high-level disinfectant onsite (CS20) was expired.Acquire suitable high-level disinfectant for use in disinfecting semi-critical tools requiring high level disinfection.
- 20. Is reusable equipment disinfected properly?
- Monitoring Inspection
2 infractions
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- 1. Lot numbers for single use, sterile needles are not being recorded with client records. Needles are being used for extractions during facial services.COMPLETE THE FOLLOWING:1. Please record lot numbers.
- 20. Is reusable equipment disinfected properly?
- **CORRECTED**1. CS20 was being diluted with water. No high-level disinfectant was detected in the soak tray. Solution was discarded during the inspection.2. Pedicure tubs were being disinfected with 99% alcohol. Advised operator that alcohol is not an accepted disinfectant for personal services facilities. COMPLETE THE FOLLOWING:1. Do not dilute CS20, as it is a ready to use solution. 2. Do not use alcohol for disinfecting pedicure tub. Use available Cavicide for the tub.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?