Aller au contenu
Chargement de la carte…

DEMO BREWING COMPANY

1763 W BERTEAU AVE, CHICAGO, IL 60613 · Restaurant (Liquor)

2 inspections

  1. Réinspection des licences

    1 infraction

    • 38. INSECTES, RODENTS ET ANIMAUX NON PRÉSENTÉS
      • 6-202.15 NOTED THAT THE SIDE EXIT DOOR TO THE BUILDING WAS NOT RODENT-PROOF, WITH GAP AT THE BOTTOM OF THE DOOR (ABOUT 1/4 INCH). INSTRUCTED TO SEAL GAPS TO PREVENT ENTRY POINTS FOR PESTS.
  2. Licence

    10 infractions

    • 3. GESTION, EMPLOYÉS ALIMENTAIRES ET EMPLOYÉS CONDITIONNELS; CONNAISSANCES, RESPONSABILITÉS ET RAPPORTS
      • NOTED NO EMPLOYEE HEALTH POLICY ON SITE AT THE TIME OF INSPECTION FOLLOWING THE NEW CODE AND GUIDELINES. INSTRUCTED TO HAVE VERIFICATION OF POLICY FOR EACH EMPLOYEE ONE ON SITE AT ALL TIMES. PRIORITY FOUNDATION #7-38-010. NO CITATION ISSUED TODAY
    • 5. PROCÉDURES DE RESPONSABILITÉ AUX ÉVÉNEMENTS DE VOTE ET DE DIARRHEAL
      • MANAGEMENT UNABLE TO PROVIDE A PROCEDURE FOR CLEANING UP VOMITING AND DIARRHEA.INSTRUCTED TO HAVE ONE INCLUDING THE CHEMICALS AND SUPPLIES NEEDED. PRIORITY FOUNDATION #7-38-005. NO CITATION ISSUED.
    • 10. AIDE À L ' AGRICULTURE PROFESSIONNELLE ET ACCESSIBLE
      • NOTED NO HAND WASH SINK SIGNAGE AT THE BAR HAND WASH SINK. INSTRUCTED TO HAVE A HAND WASH SINK SIGNAGE AT ALL HAND WASH SINKS.
    • 16. SURFACES DE CONTACT ALIMENTAIRE: ÉLÉMENTS ET SANITAIRES
      • NO DETERGENT AVAILABLE FOR 3 COMPARTMENT SINK OR WARE WASHING MACHINE. MUST PROVIDE DETERGENTS.
    • 38. INSECTES, RODENTS ET ANIMAUX NON PRÉSENTÉS
      • NOTED SIDE EXIT DOOR TO THE BUILDING NOT RODENT PROOF WITH GAP AT THE BOTTOM OF DOOR (ABOUT 1/4 INCH). INSTRUCTED TO SEAL GAPS TO PREVENT ENTRY POINTS FOR PESTS.
    • 38. INSECTES, RODENTS ET ANIMAUX NON PRÉSENTÉS
      • NOTED NO PEST CONTROL LOG BOOK ON SITE AT THE TIME OF INSPECTION. INSTRUCTED TO HAVE A COMPLETE PEST CONTROL LOG BOOK WITH A LICENSED PEST CONTROL COMPANY AT ALL TIMES. PRIORITY FOUNDATION VIOLATION #7-38-020(C). NO CITATION ISSUED.
    • 48. INSTALLÉES, PRINCIPALES ET UTILISÉES; ESSAIS
      • NOTED NO SANITIZER TEST STRIP KIT ON SITE AT THE TIME OF INSPECTION. INSTRUCTED TO HAVE A TEST STRIP KIT ON SITE AT ALL TIMES TO PROPERLY MONITOR THE STRENGTH OF THE SANITIZER. PRIORITY FOUNDATION VIOLATION #7-38-005. NO CITATION ISSUED TODAY.
    • 48. INSTALLÉES, PRINCIPALES ET UTILISÉES; ESSAIS
      • NOTED PREMISE USING A HIGH TEMPERATURE DISH WASHER WITH GAUGE READING 0F AND NOTED NO TEMPERATURE TEST STRIPS OR TEMPERATURE MEASURING DEVICE TO MONITOR THE SURFACE TEMPERATURE. INSTRUCTED TO PROVIDE AND IRREVERSIBLE REGISTERING TEMPERATURE INDICATOR, STRIPS/STICKERS. PRIORITY FOUNDATION #7-38-005. NO CITATION ISSUED TODAY.
    • 51. PLAQUEMENT INSTALLÉ; DISPOSITIFS DE RENFORCEMENT
      • NOTED NO BACK FLOW PREVENTION DEVICE LOCATED AT THE HOSE BIB NEXT TO THE UTILITY SINK AT THE REAR. INSTRUCTED TO INSTALL A BACK FLOW PREVENTION DEVICE THAT IS VISIBLE.
    • 53. INSTALLATIONS DE TOLET: CONSTRUCTION PROPRIÉTAIRE, DÉLIVRANCE ET CLÉ
      • NOTED WASH ROOM ON PREMISE WITH GARBAGE RECEPTACLES AND NO LIDS. INSTRUCTED TO PROVIDE TRASH CANS WITH LIDS AT UNISEX WASH ROOM.