278 Suder Green Drive NW - Whirlpool
278 Suder Green Drive NW Edmonton AB T6T 6V6 · Aquatic Facility
6 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on 22/08/2025 was unsatisfactory: Total Coliform present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Total alkalinity was 12ppm which was too low. Adjusted onsite.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- The donut weir and basket had separated in both skimmers and were not installed properly to be effective. Repair.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH: 6.71Operator adjusted pH during inspection onsite.pH retested 7.12
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity: 44ppmEnsure Alkalinity is in the range 60-180ppm
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Flow rate was higher (65gpm) than the max flow rate 60gpm.Adjust flow rate between 55gpm and 60gpm.