8808 165 Street NW - Swimming Pool
8808 165 Street NW Edmonton AB T5R 4L1 · Aquatic Facility
Inspection summary
8808 165 Street NW - Swimming Pool has been inspected 10 times by Alberta Health Services (Environmental Public Health) since February 29, 2024. The most recent inspection, on August 21, 2026, found no infractions.
2 of 10 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.
Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 16 times across 8 separate inspections, most recently on February 3, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Food safety training and certificationLower risk
Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.
Recorded 4 times across 4 separate inspections, most recently on January 15, 2025. For example:
Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
10 inspections
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The water level was at the level of the two skimmers at the East end of the pool. However, the water level was above the two skimmers at the West end of the pool.Corrective Action:Adjust and maintain the water level at the level of skimmers to ensure adequate skimming action and surface recirculation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- A hose was left in the pool, overfilling the basin. The water level was above the skimmers.Corrective Action:Adjust and maintain the water level at the skimmers to ensure adequate surface recirculation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample submitted on January 28, 2025, was unsatisfactory: HPC 250 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 115GPM to allow for a turnover period of less t6 hours or less.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The turnover period was 7.3 hours. A minimum flow rate of 110GPM is required to achieve a 6 hour turnover period
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 200GPM to allow for a turnover period of less t6 hours or less.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The turnover period was 7.3 hours. A minimum flow rate of 110GPM is required to achieve a 6 hour turnover period
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pool pilot indicator light was flashing red with an error message to "Add Salt"
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Aquastar A10RCFR101 suction outlet covers were non-compliant. The maximum pump flow (150GPM) exceeds the maximum approved outlet cover flow of 119GPM. To achieve compliance, new suction outlet covers with higher flow ratings need to be installed.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
4 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 200GPM to allow for a turnover period of less t6 hours or less.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The turnover period was 7.3 hours. A minimum flow rate of 110GPM is required to achieve a 6 hour turnover period
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pool pilot indicator light was flashing red with an error message to "Add Salt"
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Updated Anti-entrapment plan was not available to be reviewed onsite.Update anti-entrapment plan and email copy of update anti-entrapment plan to the undersigned.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 200GPM to allow for a turnover period of less t6 hours or less.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Updated Anti-entrapment plan was not available to be reviewed onsite.Update anti-entrapment plan and email copy of update anti-entrapment plan to the undersigned.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample submitted on December 31, 2024, was unsatisfactory: Total Coliforms isolated. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 200GPM to allow for a turnover period of less t6 hours or less.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Updated Anti-entrapment plan was not available to be reviewed onsite.Update anti-entrapment plan and email copy of update anti-entrapment plan to the undersigned.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 29 Feb 2024; The turnover period was 6.29 hours based on a flow rate of 105GPM. 9 Jan 2023; The turnover period was 6.29 hours based on a flow rate of 105GPM. Adjust the flow rate to between 110GPM and 200GPM to allow for a turnover period of less t6 hours or less.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Updated Anti-entrapment plan was not available to be reviewed onsite.Update anti-entrapment plan and email copy of update anti-entrapment plan to the undersigned.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?