Inspection summary

9 Lives Studio has been inspected 6 times by Alberta Health Services (Environmental Public Health) since October 27, 2023. The most recent inspection, on August 31, 2026, found no infractions.

3 of 6 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 2 infractions recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded 3 times across 3 separate inspections, most recently on June 1, 2026. For example: If the facility sterilizes equipment, are all proper sterilization, verification, and documentation processes in place (Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

6 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 22. If the facility sterilizes equipment, are all proper sterilization, verification, and documentation processes in place (Critical)?
      • The manufacturer's instructions/user manual for the Enbio steam sterilizer remain outstanding. Please provide the full PDF copy of the Enbio steam sterilizer manufacturer's instructions/user manual for review. A PDF copy is preferred; scanned pages are not required. Please provide the full PDF manual for review.Corrected from previous report - The Enbio cycle reports provided for loads 2675, 2857, 2864, and 2923 were reviewed. These records correspond to the load numbers reviewed during the routine inspection and include physical monitoring information, including sterilization temperature, exposure time at sterilization temperature, and pressure. The physical monitoring and load recording requirement is considered corrected based on the documentation reviewed.
  3. Monitoring Inspection

    1 infraction

    • 22. If the facility sterilizes equipment, are all proper sterilization, verification, and documentation processes in place (Critical)?
      • 1. The manufacturer's instructions for the steam sterilizer were not readily accessible at the time of inspection. Manufacturer's instructions for sterilizers must be readily accessible to personal service workers. Please ensure the manufacturer's instructions for the sterilizer are available on site for reference by personal service workers at all times.2. Physical monitoring of records for sterilized loads were not available for review at the time of inspeciton. For each sterilized load, sterilization temperature, exposure time at the sterilization temperature, and pressure, where applicable, must be monitored, verified to have met the manufacturer's specifications, and documented. Please ensure sterlilizer cycle records are maintained and readily accessible for review, including records showing the time, temperature and pressure fo each sterilized load.
  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    1 infraction

    • 22. If the facility sterilizes equipment, are all proper sterilization, verification, and documentation processes in place (Critical)?
      • New sterilizer is a steam sterilizer Enbio S. After reviewing the Quality Report provided, the corresponding biological indicator, type 5 chemical indicator and bowie tests are not included in said report. Please forward those to this office.
  6. Initial Inspection

    0 infractions