Abbey Centre McKay Ranch - Whirlpool

4500 Womacks Road Blackfalds AB T0M 0J0 · Aquatic Facility

9 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated from June 23 samples. Shock, dump, refill and retest.Update: The water sample was not submitted due to the Canada Day holiday, as laboratory operations and scheduling were affected.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Pool volume 520 US gallonsFilter area 33.80 ft sqGallons per minute 425 Maximum rate of filtration 425 GPM/33.8 sqft= 12.57 GPMPlease reduce the flow rate to 422.5 GPM or less to ensure compliance with the maximum filtration rate requirement.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Upon review, the anti-entrapment documentation indicated that each main drain is rated for a maximum flow rate of 408 GPM. The current flow rate is 425 GPM per main drain, which exceeds the cover rating. To comply with the cover rating, the flow rate through each main drain should not exceed 408 GPM. As the covers are not rated for the current flow rate either the flow rate must be lowered or covers must be replaced with a higher rating. For the mean time please ensure that the main drains are shut off and that the skimmers are set to maximum flow. Long-term solutions will be discussed, such as replacement, pressure release valve or limiting flow rate, and follow-up inspections will be conducted.It is noted that there may be discrepancy in the anti-entrapment documents. In depth analyze will be conducted in order to determine if it was documentation error.
  3. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas isolated from June 23 samples. Shock, dump, refill and retest.
  4. Risk Management Inspection

    0 infractions

  5. Risk Management Inspection

    1 infraction

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • Lines are broken and need to be shut off to prevent potential underground erosion. Scoping has been unsuccessful due to pipe joint bends. Whirlpool entrance has water overflow. Main drain is functioning and will permit turnover rates on its own.To promote a functioning system, the following will be implemented:1. Decreasing bather load to a half.2. Frequent pumping out of skimmer basins with water pump to promote skimming action.3. Increased shock chlorination of pool based on normal frequency and also elevated combined chlorine results.4. Frequent pool dump and filling. Note, the continued operation of the pool is a fluid process and likely need adjustments throughout the operating season.
  6. Monitoring Inspection

    1 infraction

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • Lines are broken and need to be shut off to prevent potential underground erosion. Scoping has been unsuccessful due to pipe joint bends. Whirlpool entrance has water overflow. Main drain is functioning and will permit turnover rates on its own.To promote a functioning system, the following will be implemented:1. Decreasing bather load to a half.2. Frequent pumping out of skimmer basins with water pump to promote skimming action.3. Increased shock chlorination of pool based on normal frequency and also elevated combined chlorine results.4. Frequent pool dump and filling. Note, the continued operation of the pool is a fluid process and likely need adjustments throughout the operating season.
  7. Demand Inspection

    1 infraction

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Lines are broken and need to be shut off to prevent potential underground erosion. Scoping has been unsuccessful due to pipe joint bends. Whirlpool entrance has water overflow. Main drain is functioning and will permit turnover rates on its own.To promote a functioning system, the following will be implemented:1. Decreasing bather load to a half.2. Frequent pumping out of skimmer basins with water pump to promote skimming action.3. Increased shock chlorination of pool based on normal frequency and also elevated combined chlorine results.4. Weekly pool dump and filling. Note, the continued operation of the pool is a fluid process and likely need adjustments throughout the operating season.
  8. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TC: 6.5ppmAlkalinity: 49ppmAlkalinity levels are slightly low. Staff had already added sodium carbonate to the water and will be adding more later to increase the alkalinity.
  9. Demand Inspection

    0 infractions