Banff Gate Mountain Resort - Outdoor Whirlpool
302 George Biggy Senior Road Dead Man's Flats AB T1W 2T8 · Aquatic Facility
32 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on June 15, 2026 had a heterotrophic plate count of 1650 cfu/ml. Treat water to remove contamination. Submit a new water sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on June 1, 2026 had Pseudomonas isolated. Close whirlpool until treatment done to remove contamination. Submit a new sample after treatment.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on June 1, 2026 had a heterotrophic plate count of 120cfu/ml. Treat whirlpool to remove contamination. Submit a new sample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample submitted on March 30, 2026 had a heterotrophic plate count of 1830 colony forming units per ml. Treat water to remove contamination. Submit a new sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on March 16, 2026 had a plate count of 230cfu/ml. Treat water to remove contamination. Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on March 9, 2026 was not tested as the id# sticker was not put on the bottle. New water sample to be submitted this week.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample from Tuesday February 17th, 2026, had an HPC of 170 CFU/ml. - Operators were informed to treat and re-sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on February 2, 2026 had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on October 1, 2025 had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
3 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on August 11, 2025 had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample taken on August 11, 2025 had a plate count of 390 cfu/ml. Treat water to remove contamination. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on July 14, 2025 had Pseudomonas isolated. Close whirlpool until a Pseudomonas disinfection is done. Resample on Monday.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample taken on July 2, 2025 had Pseudomonas isolated. Close whirlpool until Pseudomonas disinfection is done. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- March 17/25 water sample was not tested as there was no id sticker on the bottle. Resample to be submitted.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- December 30, 2024 water sample had Pseudomonas present. Treat water to remove contamination. Resample.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- November 11/24 water sample was not tested as there was no id# on the bottle and it was received by the lab over 24 hours after it was taken. Resample to be submitted tomorrow.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- August 12/24 water sample was not tested as there was no id# on the bottle. Resample to be submitted.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- March 11/24 water sample was not tested as there was no id# on the bottle. Please resample this week.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Dec. 11/23 water sample had Pseudomonas isolated. Treat water to remove contamination.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Monitoring Inspection
3 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- According to reading on vacuum and pressure gauges, the flow rate for the whirlpool is only 40gpm. Minimum required flow rate is 52.8gpm.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.Pressure gauge for circ. pump may not be accurate. Please confirm is in good working condition.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plan needs to be updated. Please provide copy of updated plan.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- Could not determine flow rate for jet pump as there was no vacuum gauge on the pump, only a pressure gauge. Flow meter and/or vacuum gauge needs to be installed.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Anti-entrapment plan may have some incorrect information. Please update and provide a copy.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?