Beauty First Brow + Wax
89-1250 South Service Rd Mississauga ON L5E 1V4 · Ear Piercing
2 inspections
- Required
2 infractions
- Did operator properly disinfect equipment and surfaces?
- Intermediate-level disinfect equipment such as nail clippers, cuticle nippers, nail drill bits, ear piercing device, single-use ink caps, tweezers and scissors used in hair removal services.
- Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
- Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
- High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
- Did operator properly use and maintain cleaning and disinfecting products?
- Ensure that disinfectants used in a personal service setting are accompanied by a drug identification number (DIN), natural product number (NPN) or Medical Devices Active Licence Listing (MDALL) assigned by Health Canada (exception is bleach/sodium hypochlorite); and used as per the manufacturer’s instructions, where available. (Show More)
- Did operator properly disinfect equipment and surfaces?
- Required
2 infractions
- Did operator properly disinfect equipment and surfaces?
- Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
- Did operator maintain client records for invasive services?
- In the client record, document lot number and expiry date of the pre-packaged sterile equipment used in the procedure.
- Did operator properly disinfect equipment and surfaces?