Best Western Plus 61095 - Hot tub

50 Westpark Boulevard Fort Saskatchewan AB T8L 0B2 · Aquatic Facility

14 inspections

  1. Risk Management Inspection

    1 infraction

    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are still some areas of the basin liner beginning to flake off. Repair those areas.
  2. Risk Management Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was measured to be 3.45ppm. Lower the combined chlorine to maximize bather comfort.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are still some areas of the basin liner beginning to flake off. Repair those areas.
  3. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Combined chlorine was measured to be 2.53ppm. Lower the combined chlorine to maximize bather comfort.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are still some areas of the basin liner beginning to flake off. Repair those areas.
  4. Monitoring Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was measured to be 200ppm. Operator to lower total alkalinity.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • There are section of the basin liner missing, and other areas where it is beginning to flake off.
  5. Monitoring Inspection

    1 infraction

    • 06. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Critical)?
      • Maximum rate of filtration of sand filters is 61 GPM. Operational flow rate was 80GPM.Reduce flow rate so that maximum rate of filtration is not exceeded.
  6. Monitoring Inspection

    1 infraction

    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • The manual chemistry records appeared prefilled. The week observed onsite was observed to have values in for the upcoming days and weekend. Ensure manual records are completed as work is being done.
  7. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on July 31,2024 indicated Pseudomonas isolated
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on July 31,2024 indicated HPC at 60
  8. Risk Management Inspection

    0 infractions

  9. Risk Management Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified pool operator needed. The operator onsite has the primer course. It appears that certification was obtained. Please send the undersigned a copy of the pool operator managing the pool in the interim.
  10. Demand Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC was adjusted during inspection.
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified pool operator needed. The operator onsite has the primer course. It appears that certification was obtained. Please send the undersigned a copy of the pool operator managing the pool in the interim.
  11. Initial Inspection

    1 infraction

    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified pool operator needed. The operator onsite has the primer course. Full licensed pool operator is needed.Operator agreed to have Ecolab certified pool operator or another BW pool operator verifying the chemical parameters until certified pool operator course obtained. Please send the undersigned a copy of the pool operator managing the pool in the interim.
  12. Initial Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC 1.36
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified pool operator needed. The operator onsite has the primer course. Full licensed pool operator is needed.
  13. Initial Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No water samples submitted since March 13
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC 0.48
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified pool operator needed. The operator onsite has the primer course. Full licensed pool operator is needed.
  14. Initial Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • No water samples submitted since March 13
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • FC 0.46
    • 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
      • Certified poool operator needed. The operator onsite has the primer course. Full licenced pool operator is needed.