Canalta Lac La Biche - Whirlpool
9905 83 Avenue Lac La Biche AB T0A 2C0 · Aquatic Facility
Inspection summary
Canalta Lac La Biche - Whirlpool has been inspected 9 times by Alberta Health Services (Environmental Public Health) since January 4, 2024. The most recent inspection, on August 24, 2026, recorded 1 infraction.
4 of 9 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 2 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 4 times across 4 separate inspections, most recently on August 24, 2026. For example:
Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 2 times across 2 separate inspections, most recently on June 16, 2026. For example:
Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
9 inspections
- Risk Management Inspection
1 infraction
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- The flow meter was not functioning properly at the time of inspection.The operator indicated that the flow meter may have been jammed and corrected the issue during the inspection. Ensure that the flow meter is routinely monitored and maintained in proper working condition to allow accurate measurement.
- 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
- Monitoring Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Pool chemistry levels, as measured with the inspector’s Pool Lab 2.0 test kit, were found to be out of acceptable range at the time of inspection, with low alkalinity (39 ppm). The operator was notified and took corrective action during the inspection. Follow-up testing showed alkalinity remained low (34 ppm). Ensure all pool chemistry parameters are consistently maintained within acceptable ranges to ensure water quality and bather safety.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Alkalinity measured 39 ppm.Ensure alkalinity is maintained from 60-180 ppm.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pool had a flow rate of 70 gpm, which equates to a turnover period of 23.4 min.Whirlpools with a volume greater than 4 cubic meters must maintain a turnover period of no more than 20 minutes.To achieve a 20 minute turnover period, the flow meter must be 80 gpm or greater.Adjust the flow rate to ensure the 20 minute turnover period is met.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The pool had a flow rate of 70 gpm, which equates to a turnover period of 24.12 min.Whirlpools with a volume greater than 4 cubic meters must maintain a turnover period of no more than 20 minutes.To achieve a 20 minute turnover period, the flow meter must be 85 gpm or greater.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Monitoring Inspection
1 infraction
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?
- The pool operator is new and has not yet obtained pool operator certification.Provide a plan of action with reasonable timelines to train the pool operator.
- 15. Has an owner or owner's agent, if any, been identified and is the pool operated and maintained by a qualified pool operator?