5702 43 Street Rimbey AB T0C 2J0 · Aquatic Facility

7 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - Total alkalinity was initially measured at 22 mg/L. A subsequent test showed an increase to 29 mg/L. To achieve compliance, please ensure that total alkalinity levels are adjusted to fall within the target range of 60-180 mg/L.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • - The emergency phone is not operational, there is no dial tone, and it is currently not possible to reach the front desk in case of an emergency. Please ensure the emergency phone is repaired to allow for easy access to emergency response.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - The pool deck shower is not operational. Please ensure the pool deck shower is repaired to allow for easy access to rinsing off before entering the pool which in turn helps to promote and maintain hygiene and the safety and cleanliness of the pool water.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Observed what appears to be green algae/biofilm on the pool basin floor throughout the swimming pool. Please ensure the algae/biofilm growth is properly removed and the pool basin is adequately cleaned and disinfected to maintain pool water quality.
  3. Demand Inspection

    5 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • - Heterotrophic plate count is 3,360 CFU per ml per 100 ml sample.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - Total alkalinity was initially measured at 22 mg/L. A subsequent test showed an increase to 29 mg/L. To achieve compliance, please ensure that total alkalinity levels are adjusted to fall within the target range of 60-180 mg/L.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • - The emergency phone is not operational, there is no dial tone, and it is currently not possible to reach the front desk in case of an emergency. Please ensure the emergency phone is repaired to allow for easy access to emergency response.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - The pool deck shower is not operational. Please ensure the pool deck shower is repaired to allow for easy access to rinsing off before entering the pool which in turn helps to promote and maintain hygiene and the safety and cleanliness of the pool water.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Observed what appears to be green algae/biofilm on the pool basin floor throughout the swimming pool. Please ensure the algae/biofilm growth is properly removed and the pool basin is adequately cleaned and disinfected to maintain pool water quality.
  4. Monitoring Inspection

    4 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • - Total alkalinity was initially measured at 22 mg/L. A subsequent test showed an increase to 29 mg/L. To achieve compliance, please ensure that total alkalinity levels are adjusted to fall within the target range of 60-180 mg/L.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • - The emergency phone is not operational, there is no dial tone, and it is currently not possible to reach the front desk in case of an emergency. Please ensure the emergency phone is repaired to allow for easy access to emergency response.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - The pool deck shower is not operational. Please ensure the pool deck shower is repaired to allow for easy access to rinsing off before entering the pool which in turn helps to promote and maintain hygiene and the safety and cleanliness of the pool water.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • - Observed what appears to be green algae/biofilm on the pool basin floor throughout the swimming pool. Please ensure the algae/biofilm growth is properly removed and the pool basin is adequately cleaned and disinfected to maintain pool water quality.
  5. Risk Management Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample submitted on September 9, 2025 contained an HPC level of 330 CFU/100 mL of sample water. Confirm that the pool's water chemistry is balanced and submit a resample at earliest opportunity. Ensure that the pool's HPC level is 100 CFU/100 mL or less.
  7. Initial Inspection

    0 infractions