Days Inn & Suites Cochrane - Whirlpool

5 Westside Drive Cochrane AB T4C 1M1 · Aquatic Facility

13 inspections

  1. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Pseudomonas aeruginosa was isolated from water sample. Treat the whirlpool basin following AHS guidelines and submit another sample.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • High Heterotrophic Plate Count of over 57,000 CFU/mL was measured from sample. Treat whirlpool and submit resample.
  2. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample collected on June 15, 2026 was Unsatisfactory. Pseudomonas: ISOLATED
  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample submitted on April 13 was Unsatisfactory.Pseudomonas: ISOLATED
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on April 13 was Unsatisfactory.HPC: >57000 CFU/mL.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on Dec. 15 was not processed by the lab due to no identification number on the bottle.
  5. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted on Dec. 15 was not processed by the lab due to no identification number on the bottle.
  6. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • *The Free Chlorine was measured greater than 8ppm, over rate. Automatic reader was showing FCL: 3. 32ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 6.8 and manual testing was under range less than 6.5.
  7. Risk Management Inspection

    0 infractions

  8. Risk Management Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • *The Free Available Chlorine was measured at 0.5 ppm.*Manual pH testing of the whirlpool water showed pH was very low, less than 6.5
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity of the whirlpool water was measured greater than 200ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 6.8 and manual testing was under range less than 6.5.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Excessive foaming was observed in the whirlpool water.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The Clock by the whirlpool area was not operational
  9. Risk Management Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • *The Free Chlorine was measured greater than 8ppm, over rate. Automatic reader was showing FCL: 3. 32ppm
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 6.8 and manual testing was under range less than 6.5.
  10. Demand Inspection

    7 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Bacteriological water sample taken from the whirlpool on November 24, 2025 had Pseudomonas PRESENT.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Bacteriological water sample taken from the whirlpool on November 24, 2025, had HPC 930cf/mL
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • *The Free Available Chlorine was measured at 0.5 ppm.*Manual pH testing of the whirlpool water showed pH was very low, less than 6.5
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity of the whirlpool water was measured greater than 200ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 6.8 and manual testing was under range less than 6.5.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Excessive foaming was observed in the whirlpool water.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The Clock by the whirlpool area was not operational
  11. Initial Inspection

    5 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • *The Free Available Chlorine was measured at 0.5 ppm.*Manual pH testing of the whirlpool water showed pH was very low, less than 6.5
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity of the whirlpool water was measured greater than 200ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated monitoring system’s chemical readings were inconsistent with manual testing. Automated reading for pH was 6.8 and manual testing was under range less than 6.5.
    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • Excessive foaming was observed in the whirlpool water.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The Clock by the whirlpool area was not operational
  12. Risk Management Inspection

    0 infractions

  13. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample from Oct. 27 was unsatisfactory. Pseudomonas: ISOLATED and HPC: 300CFU/mL.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample from Oct. 27 - HPC: 300CFU/mL.