  1. Risk Management Inspection

    2 infractions

    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.
  2. Demand Inspection

    6 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • The pH was measured at 7.61.- Drain, refill and then chemically balance the whirlpool water.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The Combined Chlorine measured 2.78 ppm.- Drain, refill and then chemically balance the whirlpool water.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • The automated reading for the pH was noted as 7.47.- Repair and/or calibrate the automated monitoring system so it provides adequate chemicals levels, and its readings are consistent with manual testing.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Chemical reagents required for the manual testing of pool water chemistry were expired and/or not available onsite.- Obtain suitable and valid chemical reagents for test kit used to perform daily and weekly testing.
  3. Risk Management Inspection

    2 infractions

    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.
  4. Monitoring Inspection

    4 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Pool Free Available Chlorine measured at 0.17ppm.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Pool pH measured at 7.84
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.
  5. Risk Management Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Pool Free Available Chlorine measured at 1.03ppm.
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.
  6. Risk Management Inspection

    3 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • Pool pH measured at 7.93
    • 13. Are the general safety devices and physical conditions in this pool providing a safe environment (Non-Critical)?
      • The clock present in the pool is not clearly visible from the whirlpool (small and dark face, hands difficult to discern from a distance). Add a clock closer to the whirlpool.
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The flow meter installed to measure the flow rate of the whirlpool's circulation system was not working at the time of inspection.Repair or replace flow meter so flow rate can be verified.