DCECC#232 Illingworth Class B Pool

10 Illingworth Ln, Ajax ON L1T 0L1 · Pool - Class B

5 inspections

  1. Routine

    1 infraction

    • Pool, deck and walls maintained in a sanitary condition, safe and free from hazards
      • Fail to maintain pool in a safe condition
      • Operator to ensure pool is maintained in a safe condition
  2. Routine

    5 infractions

    • Pool, deck and walls maintained in a sanitary condition, safe and free from hazards
      • Fail to ensure deck surfaces free from hazards
      • Operator to maintain deck surfaces free from hazards
    • Safe storage, handling and sufficient supply of all chemicals
      • Fail to provide a sufficient supply chemicals
      • Operator to ensure supply of chemicals are sufficient to operate the pool
    • Daily records completed, signed and available for viewing
      • Fail to record activation of ground fault detector during daily use period
      • Operator to ensure daily records are completed, signed and available for viewing by Medical Officer of Health or Public Health Inspector at any time
    • Other records signed and completed
      • Fail to test ground current leakage detecting and de-energizing devices monthly or according to manufacturer’s instructions, whichever is more frequent
      • Operator to ensure ground current leakage detecting and de-energizing devices are tested monthly or according to the manufacturer’s instructions, whichever is more frequent and recorded
    • Ground fault circuit interrupter (GFCI) is activated during the daily use period of the pool
      • Fail to ensure GFCI is activated during the daily use period of the pool
      • Operator to ensure GFCI is activated during the daily use period of the pool
  3. Routine

    1 infraction

    • Recirculation system of water facility is in good working condition (including automatic dosing device)
      • Fail to maintain recirculation system in good working condition
      • Operator to ensure recirculation system is maintained in good working condition
  4. Routine

    2 infractions

    • Recirculation system of water facility is in good working condition (including automatic dosing device)
      • Fail to maintain recirculation system in good working condition
      • Operator to ensure recirculation system is maintained in good working condition
    • Total alkalinity within range of 80-120 ppm
      • Fail to maintain total alkalinity within range of 80-120 ppm
      • Operator to ensure total alkalinity within range of 80-120 ppm
  5. Routine

    5 infractions

    • Recirculation system of water facility is in good working condition (including automatic dosing device)
      • Fail to maintain recirculation system in good working condition
      • Operator to ensure recirculation system is maintained in good working condition
    • pH is within range of 7.2 to 7.8
      • CLOSE POOL
      • Fail to maintain pH within acceptable range
      • Operator to ensure pH is maintained within range of 7.2 - 7.8
    • Total alkalinity within range of 80-120 ppm
      • Fail to maintain total alkalinity within range of 80-120 ppm
      • Operator to ensure total alkalinity within range of 80-120 ppm
    • If equipped with an automatic sensing device, total alkalinity, pH value, free available chlorine, total chlorine or bromine residual and water clarity are checked at least every 4 hours until the daily use period has ended
      • Fail to test total alkalinity at least every 4 hours
      • Fail to test pH at least every 4 hours
      • Fail to test free available chlorine at least every 4 hours
      • Operator to ensure all checks and tests are completed at least every 4 hours
    • Premises is maintained free from every serious condition that may be a health hazard
      • CLOSE POOL
      • Fail to ensure public pool is free from every serious condition that may be a health hazard
      • Operator to ensure public pool is free from every serious condition that may be a health hazard