Derrick Golf & Winter Club - Main Whirlpool

3500 119 Street NW Edmonton AB T6J 5P5 · Aquatic Facility

18 inspections

  1. Risk Management Inspection

    0 infractions

  2. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 26EN-092E00538 submitted on April 2, 2026, was unsatisfactory: Total coliforms present, Pseudomonas aeruginosa isolated and HPC 2520.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 26EN-092E00538 submitted on April 2, 2026, was unsatisfactory: Total coliforms present, Pseudomonas aeruginosa isolated and HPC 2520.
  3. Risk Management Inspection

    0 infractions

  4. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine residual was 2.16 ppm. Please ensure that the combined chlorine residual is maintained at the lowest level possible, and below 1 ppm.
  5. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine residual was 2.16 ppm. Please ensure that the combined chlorine residual is maintained at the lowest level possible, and below 1 ppm.
  6. Demand Inspection

    4 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 25EN-310E00599 submitted on November 6, 2025, was unsatisfactory: Total coliforms were present.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 37 ppm. Please ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration was 15.87 gpm/sq ft based on a filtration area of 12.6 sq ft and the flow rate 200 gpm. The flow rate should not exceed 155 gpm for the proper filtration rate (under 12.5 gpm/ft2).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The whirlpool water temperature was 41C. Please ensure that the whirlpool water temperature is maintained below 40C.
  7. Risk Management Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 37 ppm. Please ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration was 15.87 gpm/sq ft based on a filtration area of 12.6 sq ft and the flow rate 200 gpm. The flow rate should not exceed 155 gpm for the proper filtration rate (under 12.5 gpm/ft2).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The whirlpool water temperature was 41C. Please ensure that the whirlpool water temperature is maintained below 40C.
  8. Demand Inspection

    4 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 25EN-024E00045 submitted on January 24, 2025, was unsatisfactory: HPC 140.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 37 ppm. Please ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration was 15.87 gpm/sq ft based on a filtration area of 12.6 sq ft and the flow rate 200 gpm. The flow rate should not exceed 155 gpm for the proper filtration rate (under 12.5 gpm/ft2).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The whirlpool water temperature was 41C. Please ensure that the whirlpool water temperature is maintained below 40C.
  9. Monitoring Inspection

    3 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • Total alkalinity was 37 ppm. Please ensure that the total alkalinity is maintained between 60 and 180 ppm.
    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Rate of filtration was 15.87 gpm/sq ft based on a filtration area of 12.6 sq ft and the flow rate 200 gpm. The flow rate should not exceed 155 gpm for the proper filtration rate (under 12.5 gpm/ft2).
    • 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
      • The whirlpool water temperature was 41C. Please ensure that the whirlpool water temperature is maintained below 40C.
  10. Risk Management Inspection

    1 infraction

    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  11. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample 24EN-180E00161 submitted on June 28, 2024, was unsatisfactory: Total coliform present, Pseudomonas aeruginosa isolated and HPC over 57000.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample 24EN-180E00161 submitted on June 28, 2024, was unsatisfactory: Total coliform present, Pseudomonas aeruginosa isolated and HPC over 57000.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  12. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-24-0001901 submitted on January 4, 2024, was unsatisfactory: Total coliform present, Pseudomonas aeruginosa isolated and HPC 120.
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • the sample WE-24-0001901 submitted on January 4, 2024, was unsatisfactory: Total coliform present, Pseudomonas aeruginosa isolated and HPC 120.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  13. Risk Management Inspection

    1 infraction

    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  14. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-23-0131350 submitted on December 7, 2023, was unsatisfactory: Total coliforms present.Updated on December 11: Pseudomonas aeruginosa was isolated as well.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  15. Risk Management Inspection

    1 infraction

    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  16. Monitoring Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-23-0113349 submitted on October 19, 2023, was unsatisfactory: Pseudomonas aeruginosa isolated.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. Please provide the information for the new volume.
  17. Demand Inspection

    3 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • the sample WE-23-0113349 submitted on October 19, 2023, was unsatisfactory: Pseudomonas aeruginosa isolated.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Cement was added to the bottom of the pool basin to increase the sump depth. The changes in pool volume and anti-entrapment compliance have not been reflected in the anti-entrapment compliance plan and the compliance has not been confirmed.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. The changes in pool volume and anti-entrapment compliance have not been reflected in the anti-entrapment compliance plan and the compliance has not been confirmed.
  18. Risk Management Inspection

    2 infractions

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • Cement was added to the bottom of the pool basin to increase the sump depth. The changes in pool volume and anti-entrapment compliance have not been reflected in the anti-entrapment compliance plan and the compliance has not been confirmed.
    • 18. Have plans for construction, renovations or alteration for the pool been submitted for written approval?
      • Cement was added to the bottom of the pool basin to increase the sump depth. The changes in pool volume and anti-entrapment compliance have not been reflected in the anti-entrapment compliance plan and the compliance has not been confirmed.