Skip to content
Loading map…

Element Vaughan Southwest

6170 Highway 7, Vaughan, ON, L4H 0R2 · Class B, Whirlpool/Spa

Inspection summary

Element Vaughan Southwest has been inspected 9 times by York Region Public Health since January 8, 2025. The most recent inspection, on October 7, 2026, found no infractions.

7 of 9 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 14 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 3 times on September 18, 2026. For example: Total alkalinity is within required range

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times on September 18, 2026. For example: Daily records completed and signed

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 9 times across 2 separate inspections, most recently on September 25, 2026. For example: Hydro-massage jet fittings equipped with timing device

About this data

These results come from York Region Public Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Re-inspection

    0 infractions

  2. Re-inspection

    1 infraction

    • Hydro-massage jet fittings equipped with timing device
      • Fail to ensure timing device can be set to 15 minute maximum
  3. Compliance Inspection

    13 infractions

    • Total alkalinity is within required range
      • Fail to maintain total alkalinity in range of 60 - 180 ppm
    • pH is within required range
      • Fail to maintain pH within range of 7.2 to 7.8
    • Free available chlorine (FAC) residual is within required range
      • Fail to maintain free available chlorine (FAC) residual between 5 - 10 ppm (Spa, Wading Pool, Hot Water Pool, Cold Plunge Pool, Floatation Pool)
    • Oxidation Reduction Potential (ORP) value is within range of 600 mV - 900 mV (if equipped with automatic sensing device)
      • Fail to maintain ORP value between 600-900 mV
    • Facility conducts required tests at appropriate intervals, as required
      • Fail to manually test TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) 30 minutes prior to opening
      • Fail to check TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) at least every 4 hours during daily use period where automatic sensing device is used
    • Daily records completed and signed
      • Fail to keep daily record of estimated number of bathers during operating day
      • Fail to record reading of the make-up water meter
      • Fail to record TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) 30 minutes before opening the facility
      • Fail to record TA, pH, FAC, TC or TBr, water clarity and water temperature (Spa, Hot Water Pool) at least every 4 hours during daily use period where automatic sensing device is used
      • Fail to record results of the emergency telephone test and time of day test was performed
    • Other tests and records completed and signed
      • Fail to ensure water, gravity, and suction outlet covers are inspected at least once in each 30 day operating period
      • Fail to test ground current leakage detecting and de-energizing device at least once monthly or according to manufacturer's instructions, whichever is more frequent
      • Fail to ensure emergency stop button is tested at least once in each 30 day operating period
      • Fail to record the time of day the emergency stop button test was performed
      • Fail to ensure vacuum release mechanism is tested and inspected at least once in each 30 day operating period
    • Emergency telephone is present, operational and tested daily
      • Fail to provide emergency telephone operational and in good working order
      • Fail to test emergency telephone before facility is opened for use each day
    • Ground current leakage detecting and de-energizing device provided and functional where required
      • Fail to provide ground current leakage detecting and de-energizing device where required
    • Hydro-massage jet fittings equipped with timing device
      • Fail to ensure timing device can be set to 15 minute maximum
    • Operator is designated and trained
      • Fail to provide operator trained in recreational water facility operation and maintenance, filtration systems, water chemistry and all relevant safety and emergency procedures.
    • All components of the facility maintained in proper working order
      • Fail to ensure all components of the facility unit are maintained in proper working order
    • The premise appears to be free from conditions that might be a health hazard
      • Fail to maintain facility in safe condition
  4. Compliance Inspection

    0 infractions

  5. Compliance Inspection

    0 infractions

  6. Compliance Inspection

    0 infractions

  7. Compliance Inspection

    0 infractions

  8. Compliance Inspection

    0 infractions

  9. Compliance Inspection

    0 infractions

Nearby inspected facilities