Forest City Estates - Pool

390 Southdale Rd E, London ON N6E 1V8 · Pool - Class B (Outdoor)

6 inspections

  1. Required

    4 infractions

    • Water facility and equipment maintained in a safe and sanitary condition
      • Fail to ensure water facility and/or equipment maintained in a safe and sanitary manner
    • Notices displayed as required
      • Fail to ensure notice sign is posted at the emergency phone stating the full name and address of the public pools location and emergency phone numbers
    • Markings displayed as required
      • Fail to display markings setting out breaks between gentle and steep bottom slopes and shallow points
    • Premises is operated and maintained free from every condition that may be an immediate health hazard
  2. Required

    2 infractions

    • Notices displayed as required
    • Markings displayed as required
  3. Required

    0 infractions

  4. Required

    4 infractions

    • Pool enclosure and/or area maintained in a sanitary condition and free from hazards
      • Fail to ensure deck surfaces free from hazards
    • Emergency telephone is confirmed in operating condition before opening each day
      • Fail to ensure emergency telephone is confirmed operational before opening each day
    • Notices displayed as required
    • Premises is operated and maintained free from every condition that may be an immediate health hazard
  5. Follow-up

    0 infractions

  6. Required

    5 infractions

    • Pool enclosure and/or area maintained in a sanitary condition and free from hazards
      • Fail to ensure deck surfaces free from hazards
    • Total alkalinity maintained within required range
      • Fail to ensure total alkalinity maintained between 80 ppm to 120 ppm
    • Daily records completed and sign
      • Fail to keep and record estimated number of bathers
      • Fail to keep and record make-up water reading
    • Other records
      • Fail to ensure all water, gravity and suction outlet covers are inspected at least once every 30 operating days
      • Fail to ensure test buttons associated with ground current leakage detecting or de-energizing devices tested monthly or according to manufacturer’s instructions, whichever is more frequent
      • Fail to ensure written record of each inspection is made and signed by the person who performed the inspection
    • Markings displayed as required
      • Fail to display markings in figures not less than 100 mm high setting out water depths (areas greater than 2.5 m)
      • Fail to display markings setting out breaks between gentle and steep bottom slopes and shallow points