Gleniffer Lake Resort - South Hot Tub Indoor
35468 Range Road 30 Red Deer County AB T0M 1V0 · Aquatic Facility
Inspection summary
Gleniffer Lake Resort - South Hot Tub Indoor has been inspected 14 times by Alberta Health Services (Environmental Public Health) since December 17, 2024. The most recent inspection, on September 14, 2026, recorded 1 infraction.
None of the 14 inspections on record were free of infractions. In the past 12 months there were 6 inspections with 8 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality, Food temperature control and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 19 times across 14 separate inspections, most recently on September 14, 2026. For example:
Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
Food temperature controlHigher risk
Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.
Recorded 2 times across 2 separate inspections, most recently on December 24, 2024. For example:
Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded once on August 28, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
14 inspections
- Risk Management Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory water sample received. Sample was collected on September 2, 2026.HPC: 3210 CFU/mlPlease treat the whirlpool to resolve this. Guidance on the recommended treatment and disinfection procedures can be found at the following link:https://www.albertahealthservices.ca/assets/wf/eph/wf-eph-interpret-microbiological-sample-results-pools.pdf
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Monitoring Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Risk Management Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. Routine water sample result: Pseudomonas PresentClose the pool from public use immediately. Drain and thoroughly clean and sanitize the pool basin and all accessible surfaces. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 2.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. Routine water sample result: Pseudomonas PresentClose the pool from public use immediately. Drain and thoroughly clean and sanitize the pool basin and all accessible surfaces. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 2.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- 1. FC was 1.9. Operator adjusted feed and brought FC back within acceptable limits quickly.Water Chemistry: FC 4.2 pH 7.1
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Risk Management Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. Routine water sample result: HPC – 220 CFU/ml / PseudomonasClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is peeling paint on the ceiling and the walls in the pool area due to a roof leak. The windows that separate the pool from the common hallway are cracked. The pool deck is not getting cleaned and sanitized daily. The scum lines are becoming visible in the pool basin. The metal frames on the windows is rusting and staining the walls. There are some missing and cracked tiles in the pool basin.Facility will be closing in the winter for routine maintenance and work will be completed then. Please ensure all work is completed by April 1, 2024. If work is completed before then, let me know and I will do a reinspection sooner.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. Routine water sample result: HPC – 200 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Anti-entrapment plan updates provided, the following is outstanding: Two pumps are included on the plan. Maximum flow rating for each is required. The operator will confirm interconnectedness of sumps and pumps. Drawings available were proposed plans and likely do not represent what is in place. Operator is aware that if the jet pump is pulling from single main drain in basin - that a secondary anti-entrapment device will be required. Prior to purchase and install, the operator will provide the health inspector with the type, make and model of the secondary anti-entrapment device. Pumps:Champion 56 frame (recirc) and B&D BDXBTVAR300. Max flow of each pump separately to be determined. Picture of flow meter provided. Variable speed B&D pump, must be turned to its highest speed and flow measured. Ensure filters backwashed, skimmers turned off to get the reading. 2" lines out sumps for both recirculation and jet pumps. Covers:One cover has been replaced as it was cracked. Certificates of compliance provided for the new one and existing covers. Existing covers expire Sept 16, 2025. New cover will expire October 1, 2030 as there is a 7 year expiry from date of install. Please update new cover date in anti-entrapment plan. Covers are ANSI/APSP-16 compliant. Photo of new cover provided. SumpHayward WG1154AV sumps, and covers are WG1048E with corresponding WG1056C rings. Drawing and photos of sumps provided. No equalizer lines in placeActions: 1) Determine interconnectedness of sumps/pumps. If a single main drain situation exists, secondary anti-entrapment required - must be approved by health inspector prior to purchased and install. 2) Provide drawing that shows current piping schematic from hot tub basin to pump in mechanical room. 3) get max flow rates for each pump independently4) Update anti-entrapment plan and submit to health inspector.
- 14. Is the pool maintained in a clean and sanitary condition, good repair and are temperatures being properly regulated?
- There is peeling paint on the ceiling and the walls in the pool area due to a roof leak. The windows that separate the pool from the common hallway are cracked. The pool deck is not getting cleaned and sanitized daily. The scum lines are becoming visible in the pool basin. The metal frames on the windows is rusting and staining the walls. There are some missing and cracked tiles in the pool basin.Facility will be closing in the winter for routine maintenance and work will be completed then. Please ensure all work is completed by April 1, 2024. If work is completed before then, let me know and I will do a reinspection sooner.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?