Glowing Spirit Esthetics
5614 52 Avenue St. Paul AB T0A 3A1 · Personal Services
6 inspections
- Monitoring Inspection
0 infractions
- Monitoring Inspection
0 infractions
- Demand Inspection
0 infractions
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Initial Inspection
5 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- The following written records were unavailable:- the cleansing of skin and mucous membrane- application of antiseptic products- decontamination of any sink that will be used for both handwashing and equipment reprocessing- client care in the event of an accidental skin cut or puncture
- 20. Is reusable equipment disinfected properly?
- Operator noted using low level disinfectant (LLD) for the re-usable components of the microdermabrasion that come in contact with client skin. Semi-critical instruments should be disinfected with a High-level disinfectant such as PREempt CS 20.
- 20. Is reusable equipment disinfected properly?
- No High-Level Disinfectant (HLD) test strips available onsite. Test strip requirements are specified by the disinfectant manufacturer and must be used to test disinfectant each day that it is used.
- 20. Is reusable equipment disinfected properly?
- High Level Disinfectant Log was unavailable. Reusable high-level disinfectant (HLD) must be tested daily to confirm its minimum effective concentration (MEC).
- 33. Are general nuisance conditions, other than those noted in other violations, being prevented at this personal services facility (Non-Critical)?
- Surface disinfectant (PREempt RTU) was noted to have expired January 2023
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?