Harbourview Condominiums Spa - Indoor Pool

89 Pine Street Sault Ste. Marie ON P6A 3Y3 · Indoor Pool

Inspection summary

Harbourview Condominiums Spa - Indoor Pool has been inspected 9 times by Algoma Public Health since June 27, 2024. The most recent inspection, on July 31, 2026, found no infractions.

5 of 9 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 0 infractions recorded. The higher-risk findings here relate to: Cleaning and sanitizing and Pool and spa water quality.

The last 4 inspections in a row found no infractions. Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Cleaning and sanitizingHigher risk

    Decks, change rooms, showers and shared equipment must be cleaned and disinfected regularly so infections such as athlete's foot and plantar warts are not passed between users.

    Recorded once on July 8, 2025. For example: Automatic sensing device providing sufficient monitoring and sanitization of the spa

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded once on June 27, 2024. For example: A clock is in sight for all users of the spa [Sec. 24]

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 3 times across 2 separate inspections, most recently on July 7, 2025. For example: The hydro-massage jets are controlled by an adjacent timing device [Sec. 21]

About this data

These results come from Algoma Public Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

9 inspections

  1. Required

    0 infractions

  2. Required

    0 infractions

  3. Required

    0 infractions

  4. Required

    0 infractions

  5. Follow-up

    1 infraction

    • Automatic sensing device providing sufficient monitoring and sanitization of the spa
      • Oxidation reduction potential (ORP) must be at a range of 600-900 mV [Sec. 7(8)(f)]
  6. Required

    2 infractions

    • The hydro-massage jets are controlled by an adjacent timing device [Sec. 21]
      • The timing device must control the period of operation of the jet pump to a maximum time interval of 15 minutes [Sec. 22(1)(b)]
    • Total Bromine (Br) residual maintained between 5 ppm – 10 ppm [Sec. 7(8)(c)]
      • The bromine level must be adjusted to the range of 5 ppm – 10 ppm in every part of the spa [Sec. 7(8)(c)]
  7. Required

    0 infractions

  8. Required

    1 infraction

    • Total Bromine (Br) residual maintained between 5 ppm – 10 ppm [Sec. 7(8)(c)]
      • The bromine level must be adjusted to the range of 5 ppm – 10 ppm in every part of the spa [Sec. 7(8)(c)]
  9. Required

    1 infraction

    • A clock is in sight for all users of the spa [Sec. 24]
      • A clock must be installed in a location that can be viewed by all users of the spa [Sec. 24]