Skip to content
Loading map…

Hastings Lake Bible Camp - Outdoor Pool

135 - 51263 Range Road 204 Sherwood Park AB T8G 1E9 · Aquatic Facility

Inspection summary

Hastings Lake Bible Camp - Outdoor Pool has been inspected 7 times by Alberta Health Services (Environmental Public Health) since June 19, 2024. The most recent inspection, on July 14, 2026, found no infractions.

3 of 7 inspections on record found no infractions at all. In the past 12 months there were 2 inspections with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 2 times across 2 separate inspections, most recently on September 23, 2024. For example: Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded once on July 9, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Food safety training and certificationLower risk

    Many jurisdictions require trained pool operators and certified lifeguards. These findings mean required training, certification or staffing records were missing at the time of inspection.

    Recorded 2 times across 2 separate inspections, most recently on July 2, 2024. For example: Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

7 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The total alkalinity was above the measurable range.
  3. Monitoring Inspection

    0 infractions

  4. Risk Management Inspection

    0 infractions

  5. Demand Inspection

    1 infraction

    • 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
      • The anti-entrapment assessment revealed that skimmer equalizer lines are missing covers.ACTION REQUIRED:1) Install covers on the equalizer lines or disable them.
  6. Risk Management Inspection

    1 infraction

    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan was submitted and has been reviewed. From the information provided in the plan and information gathered during a site visit, additional information is required to determine if the anti-entrapment plan is compliant or not:- The plan states a maximum flow rate of 123gpm, determined by a flow meter. The picture of the flow meter provided with the report does not show any reading. Also, the scale/grading on the flow meter is faded and hard to read. From the pump curve, the max flow rate for each pump is 146gpm- A hand drawn diagram was submitted as proof that the submerged suction outlets are interconnected. This is not acceptableThe following actions or additional information is required:1) Replace the flow meter with a proper flow meter that can be read. Run the pumps to max speed, take a picture of the max flow rate on the flow meter and send to me. You can also determine the max flow by using the pump curve2) Contract the services of a third party to perform line tracing to determine if the submerged suction outlets are interconnected3) Contract the services of a third party to determine how the pumps are connected to the submerged suction outlets.4) The plan show that the main drain covers are expired. If they have been replaced, please provide evidence of newly installed covers and their expiry dates.5) Provide the actual distance between drain covers
  7. Monitoring Inspection

    2 infractions

    • 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
      • Flow rate as read by the operator was 125gpmPool volume provided by operator = 276000L/72911gals**Turnover = 72911gals/125gpm/60 = 9.7 hoursFiltration rate = 125gpm/14.12sq.ft = 8.85gpm/sq.ft- Adequate skimming was observed.ACTION REQUIRED:1) Increase the flow rate to a minimum of 152gpm to achieve the minimum turnover of 8 hours.
    • 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
      • An anti-entrapment plan was submitted and has been reviewed. From the information provided in the plan and information gathered during a site visit, additional information is required to determine if the anti-entrapment plan is compliant or not:- The plan states a maximum flow rate of 123gpm, determined by a flow meter. The picture of the flow meter provided with the report does not show any reading. Also, the scale/grading on the flow meter is faded and hard to read. from the pump curve, the max flow rate for each pump is 146gpm- A hand drawn diagram was submitted as proof that the submerged suction outlets are interconnected. This is not acceptableThe following actions or additional information is required:1) Replace the flow meter with a proper flow meter that can be read. Run the pumps to max speed, take a picture of the max flow rate on the flow meter and send to me. You can also determine the max flow by using the pump curve2) Contract the services of a third party to perform line tracing to determine if the submerged suction outlets are interconnected3) Contract the services of a third party to determine how the pumps are connected to the submerged suction outlets.4) The plan show that the main drain covers are expired. If they have been replaced, please provide evidence of newly installed covers and their expiry dates.5) Provide the actual distance between drain covers
Own this business? Add a badge to your website