  1. Monitoring Inspection

    0 infractions

  2. Risk Management Inspection

    0 infractions

  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Unsatisfactory result for pool water sample collected on 09 Dec 2025.TC -AbsentHPC-210 CFU/mL* Ensure the pool is closed. Treat the pool, balance the chemistry and resample by Tuesday next week.
  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC at 1,900 CFU/mL.Treat the pool, balance the chemistry and resample.
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on Feb 18/2025 was not processed by the lab. Received more than 24 hrs after collection.
  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on Nov 19,2024 was unsatisfactory. High HPC of 500 in the sample result.Ensure to treat the pool as required and submit another sample at the earliest convenience.
  10. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample from Monday October 23rd was not processed by the lab, missing Identification number on the sample bottle. - Operators were informed to submit a re-sample.
  11. Monitoring Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC of 160 was noted in the sample. Pool should be shock-chlorinated to help get rid of contamination.
  13. Monitoring Inspection

    0 infractions

  14. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample came back with an HPC of 350.