Hotel Clique - South Hot Tub has been inspected 16 times by Alberta Health Services (Environmental Public Health) since April 29, 2024. The most recent inspection, on May 29, 2026, recorded 1 infraction.

None of the 16 inspections on record were free of infractions. In the past 12 months there were 4 inspections with 6 infractions recorded. The higher-risk findings here relate to: Chemicals and toxic substances and Pool and spa water quality.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 17 times across 16 separate inspections, most recently on May 29, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 6 times across 6 separate inspections, most recently on May 15, 2026. For example: Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?

  • Permits, records and postingLower risk

    Operating permits, water-test logs, posted bather rules and emergency procedures. Daily test logs are how operators show the water was checked and treated between inspections.

    Recorded 2 times across 2 separate inspections, most recently on March 3, 2025. For example: Are proper testing, monitoring, and other records being properly maintained?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

16 inspections

  1. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA measured 51 ppm at the time of inspection. **Ensure TA is maintained between 60 and 180 ppm at all times.
  2. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on May 5, 2026, was not tested because the water sample was received more than 24 hours after collection.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA measured 51 ppm at the time of inspection. **Ensure TA is maintained between 60 and 180 ppm at all times.
  3. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA measured 51 ppm at the time of inspection. **Ensure TA is maintained between 60 and 180 ppm at all times.
  4. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample that was collected on October 17, 2025, was not tested because the time of collection was not indicated. Another water sample must be submitted for testing.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA measured 51 ppm at the time of inspection. **Ensure TA is maintained between 60 and 180 ppm at all times.
  5. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • TA measured 51 ppm at the time of inspection. **Ensure TA is maintained between 60 and 180 ppm at all times.
  6. Monitoring Inspection

    1 infraction

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On July 10th, 2025 the Free Chlorine Level was measured at 1.33 ppm.During the inspection operator adjustedFinal reading 3.77 ppm.Required: Ensure that FAC is always above 2.0ppm minimum.
  7. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  8. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted May 22, 2025, had a HPC count of 130 CFU/ml, which is higher than the required limit. **Please begin treatment for the pool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  9. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted May 8 , 2025 had a HPC count of 330 CFU/ml, which is higher than the required limit. **Please begin treatment for the pool immediately. **Submit a re-sample after the treatment is completed and water chemistry is re-balanced.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  10. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample submitted March 20 , 2025 could not be tested as it was received more than 24 hours after it was collected.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  11. Demand Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Feb 27 water sample not processed due to form error..UpdateSample collected February 28, 2025, late afternoon was submitted to Foothills Lab. Lab did not receive it until Saturday , March 1 at which time they would not process as it was a non-urgent sample submitted on weekend.Action Taken/RequiredWill resample and submit on regular sampling day Thursday, March 6, 2025
  12. Demand Inspection

    2 infractions

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
    • 16. Are proper testing, monitoring, and other records being properly maintained?
      • Feb 27 water sample not processed due to form error..
  13. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.On December 20, 2024, the combined chlorine level was measured at 2.93 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  14. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The water sample collected on August 02, 2024, had an HPC count of 320 CFU/mL.REQUIREMENT: Please review the water chemistry and begin treatment for the south whirlpool. Collect and send a re-sample after you complete necessary treatments and when the water chemistry is balanced. Indicate on the requisition form that the sample is a ‘resample’
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  15. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.
  16. Monitoring Inspection

    2 infractions

    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • On April 29, 2024, the free chlorine level was measured at 1.49 ppm.REQUIREMENT: Maintain the FCL at a minimum or 2.0 ppm.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • On April 29, 2024, the combined chlorine level was measured at 1.30 ppm.REQUIREMENT: Maintain the combined chlorine level to the lowest level possible.