J Eyebrow & Lip
1011 Daniels Loop SW Edmonton AB T6W 4C9 · Personal Services
2 inspections
- Risk Management Inspection
0 infractions
- Monitoring Inspection
12 infractions
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
- No written procedures for skin cleansing prior to services and antiseptic use were available.
- 10. Is cleansing and antisepsis of skin and mucous membrane performed in accordance to written procedures and are suitable products being used?
- An antiseptic product was not being used to clean the client's skin prior to treatment. Ensure the client's skin is cleaned with a product labeled as an antiseptic prior to microblading/semi-permanent makeup services. Updated on July 9, 2025:1. Unacceptable antiseptic product was used for skin preparation: no DIN or NPN was available.
- 12. Are personal services workers at the facility maintaining client records and where applicable, sterility documentation corresponding to that client?
- Record keeping regarding which sterilized equipment was being used on which client (and on which day) was not being maintained. Ensure tracking information for each needle used is attached to the client form (so it is clear which client, had which needle, and on which day). Updated on July 9, 2025;1. Sterility assurance documentation for sterile equipment was not retained with the clients' records. Ensure that sterility assurance documentation for all critical equipment used during services is retained with clients' forms.
- 14. Is single-use or uncleanable equipment being used as intended (Non-Critical)?
- No product for cleaning make-up brushes between the clients was available.
- 20. Is reusable equipment disinfected properly?
- No approved disinfectant was used for permanent make-up machine disinfection (alcohol was used). Obtain a proper disinfectant.
- 20. Is reusable equipment disinfected properly?
- No soaking tray was available for disinfection of the tweezers. The semi-critical tools must be disinfected by soaking in a high-level disinfectant.
- 20. Is reusable equipment disinfected properly?
- No records of testing of high-level disinfectant were available, and no testing of disinfectant has been conducted as required.
- 20. Is reusable equipment disinfected properly?
- No test strips were available to test the concentration of high-level disinfectant. Obtain the appropriate strips.
- 20. Is reusable equipment disinfected properly?
- No approved disinfectant has been used for tools disinfection. Approved high-level disinfectant is required.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Numbing cream expired in August 2024.
- 26. Are cosmetic products appropriate for their intended use and being handled properly?
- Some cosmetic products did not have appropriate labels: Cleansing Water and Keratin Booster labels were in Korean only. Ensure that all cosmetic products have appropriate labels.
- 30. Is the reprocessing area of a personal service facility that uses reusable equipment properly designed, managed and maintained to ensure the safety of clients?
- The reprocessing area was located in the bathroom. Bathroom sink was used for tools washing. Provide a designated reprocessing sink, which is not located in the bathroom.
- 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?