Jericho Tennis Club - Whirlpool has been inspected 23 times by Vancouver Coastal Health since October 24, 2017. The most recent inspection, on September 29, 2026, recorded 2 infractions.

9 of 23 inspections on record found no infractions at all. In the past 12 months there were 5 inspections with 10 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Food temperature control.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 28 times across 13 separate inspections, most recently on September 29, 2026. For example: The operator maintains the pool in good repair.

  • Food temperature controlHigher risk

    Inspectors check that anything that has to be kept at a set temperature, such as chilled or hot food, or equipment like sterilizers, stays in its safe range and that accurate thermometers are on hand. With food, temperature problems are one of the most common causes of food poisoning.

    Recorded 3 times across 3 separate inspections, most recently on June 23, 2026. For example: The pool water temperature is properly maintained

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 2 times across 2 separate inspections, most recently on September 29, 2026. For example: Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

23 inspections

  1. Routine Follow-up

    2 infractions

    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  2. Routine Follow-up

    0 infractions

  3. Routine

    5 infractions

    • The pool water temperature is properly maintained
      • The hot tub temperature is in excess of 40°C
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • Pool rules are posted prominently within the pool enclosure
      • Safety rules sign missing, incomplete, or not clearly visible to the public
      • “No lifeguard on duty” sign missing, incomplete, or not clearly visible to the public at the entrance
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Procedures in the pool safety plan are not being followed.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  4. Routine Follow-up

    0 infractions

  5. Routine

    3 infractions

    • The pool alkalinity is properly maintained
      • Total Alkalinity is too high and is not at a level to maintain chemically balanced pool water.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Procedures in the pool safety plan are not being followed.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  6. Routine Follow-up

    3 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Total Alkalinity is too high and is not at a level to maintain chemically balanced pool water.
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  7. Routine

    0 infractions

  8. Routine

    2 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  9. Routine Follow-up

    0 infractions

  10. Routine

    3 infractions

    • The pool water temperature is properly maintained
      • The hot tub temperature is in excess of 40°C
    • The pool alkalinity is properly maintained
      • Total Alkalinity is too high and is not at a level to maintain chemically balanced pool water.
    • The pool does not present any suction or entrapment hazards to pool patrons
  11. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • The operator maintains the pool in good repair.
  12. Routine

    4 infractions

    • The pool pH level is properly maintained
    • Pool water velocity and recirculation rate is properly maintained
      • The pool water is not being recirculated at the design flow rate.
    • The operator maintains the pool in good repair.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Pool safety plan is not adequately developed.
  13. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  14. Routine

    4 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  15. Routine Follow-up

    0 infractions

  16. Routine

    1 infraction

    • The pool water temperature is properly maintained
      • The hot tub temperature is in excess of 40°C
  17. Request

    0 infractions

  18. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
  19. Routine

    0 infractions

  20. Routine

    0 infractions

  21. Routine

    0 infractions

  22. Routine

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  23. Routine

    1 infraction

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8