Leisure Campground and Cabins - Pool
S 26-36-25 W4 Pine Lake AB T0M 1S0 · Aquatic Facility
22 inspections
- Risk Management Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 10, 2025: Water sample was reported to have >57,000 CFU/mL of HPC. September 4, 2025: Water sample was reported to have 390 CFU/mL of HPC. August 27, 2025: Unsatisfactory routine water sample result: HPC 2240 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 10, 2025: Water sample was reported to have >57,000 CFU/mL of HPC. September 4, 2025: Water sample was reported to have 390 CFU/mL of HPC. August 27, 2025: Unsatisfactory routine water sample result: HPC 2240 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 10, 2025: Water sample was reported to have >57,000 CFU/mL of HPC. September 4, 2025: Water sample was reported to have 390 CFU/mL of HPC. August 27, 2025: Unsatisfactory routine water sample result: HPC 2240 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- September 4, 2025: Water sample was reported to have 390 CFU/mL of HPC. August 27, 2025: Unsatisfactory routine water sample result: HPC 2240 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Unsatisfactory routine water sample result: HPC 2240 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. Routine water sample result: HPC – 1570 CFU/mlClose the pool from public use immediately. Shock chlorinate the pool. After shock chlorinating, backwash the filter. Re-balance the water chemistry to bring the free chlorine level to at least 1.0ppm. The pool can then be re-opened to the public.Resample on your regular sampling day
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Originally Cited 30 Jul 2025The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.July 30, 2025.Observed readings were:Flow rate: 90 gpm.Please follow the advice of your district inspector to ensure adequate filtration and safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.July 30, 2025.Completed anti-entrampment plan not observed at the time of inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The July 16, 2025 water sample was reported to measure 1,330 CFU/mL of HPC in the sample.Please ensure that the chemical parameters are reviewed, any necessary treatment is completed, and a re-sample is submitted.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 90 GPM) 171 GPM or 647.31 LPM at the time of inspection. The turnover rate of the pool is 211,000L/647.31/60 = 5.43 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 302.83 LPM/0.45 sq meters = 672.96 LPM/sq meters or 16.33 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 340.69 LPM/0.45 sq meters = 757.09 LPM/sq meters or 18.36 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (80 GPM and 90 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
3 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pool chemistry was measured as follows:- pH: 7.73, 7.73- Free chlorine: 6.9 ppmPlease ensure that the pH is maintained within a range of 6.8-7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 88 GPM) 169 GPM or 639.73 LPM at the time of inspection. The turnover rate of the pool is 211,000L/639.73/60 = 5.50 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 306.62 LPM/0.45 sq meters = 681.38 LPM/sq meters or 16.5 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 333.12 LPM/0.45 sq meters = 740.27 LPM/sq meters or 17.96 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (88 GPM and 81 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on June 18, 2025 was reported to have the presence of Total Coliforms. Please ensure that a re-sample is submitted and the pool system parameters are reviewed. Any potential concerns should be addressed accordingly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 18, 2025 was reported to have greater than 57,000 CFU/mL of HPC. The water sample collected on September 10, 2024 was reported to be unsatisfactory for HPC, measuring at 430 CFU/mL.Please ensure that a re-sample is submitted as discussed.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pool chemistry was measured as follows:- pH: 7.73, 7.73- Free chlorine: 6.9 ppmPlease ensure that the pH is maintained within a range of 6.8-7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 88 GPM) 169 GPM or 639.73 LPM at the time of inspection. The turnover rate of the pool is 211,000L/639.73/60 = 5.50 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 306.62 LPM/0.45 sq meters = 681.38 LPM/sq meters or 16.5 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 333.12 LPM/0.45 sq meters = 740.27 LPM/sq meters or 17.96 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (88 GPM and 81 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
5 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on June 18, 2025 was reported to have the presence of Total Coliforms. Please ensure that a re-sample is submitted and the pool system parameters are reviewed. Any potential concerns should be addressed accordingly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 18, 2025 was reported to have greater than 57,000 CFU/mL of HPC. The water sample collected on September 10, 2024 was reported to be unsatisfactory for HPC, measuring at 430 CFU/mL.Please ensure that a re-sample is submitted as discussed.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pool chemistry was measured as follows:- pH: 7.85 and 7.93- Free chlorine: OR, 10.32 ppm- Cyanuric acid: 12 ppmPlease ensure that the pH is maintained within a range of 6.8-7.6.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of (81 GPM + 88 GPM) 169 GPM or 639.73 LPM at the time of inspection. The turnover rate of the pool is 211,000L/639.73/60 = 5.50 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 306.62 LPM/0.45 sq meters = 681.38 LPM/sq meters or 16.5 GPM/sqft which is outside the values noted in the Pool Standards. - Filter 2 is 333.12 LPM/0.45 sq meters = 740.27 LPM/sq meters or 17.96 GPM/sq ft which is outside the values noted in the Pool Standards. Flow rate that was observed for each filter (88 GPM and 81 GPM) are within the manufacturer's instructions for the filtration flow rate of 98 GPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate filtration and pool water turnover, as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
4 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The water sample collected on June 18, 2025 was reported to have the presence of Total Coliforms. Please ensure that a re-sample is submitted and the pool system parameters are reviewed. Any potential concerns should be addressed accordingly.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on June 18, 2025 was reported to have greater than 57,000 CFU/mL of HPC. The water sample collected on September 10, 2024 was reported to be unsatisfactory for HPC, measuring at 430 CFU/mL.Please ensure that a re-sample is submitted as discussed.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The water sample collected on September 10, 2024 was reported to be unsatisfactory for HPC, measuring at 430 CFU/mL.Please ensure that a re-sample is submitted as discussed.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The August 7, 2024 water result was reported to be unsatisfactory with HPC measured at 1080 CFU/mL.Please ensure that a re-sample is submitted.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A water sample has yet to be submitted this year according to the lab.Please ensure that a sample is submitted prior to opening the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Additional information is required to complete anti-entrapment review.Please provide requested information.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Monitoring Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- A water sample has yet to be submitted this year according to the lab.Please ensure that a sample is submitted prior to opening the pool.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The volume of the pool is 211,000 Liters. Flow meters were observed to be at a combined rate of 760 LPM at the time of inspection. The turnover rate of the pool is 211,000L/(345LPM + 403LPM)/60 = 4.70 hours which has been allowed per previous EPH approval.The two sand filters of the pool are a Hayward Pro Series sand filter (model number S310T2). - Surface area of each filter is 4.9 sq ft or 0.45 sq meters. - The max filtration rate for each filter is 20 GPM/sq ft or 814 LPM/sq meter. - The max filtration flow rate 98 GPM or 370 LPM as per the manufacturer's spec plate. The maximum rate of filtration for - Filter 1 is 345 LPM/0.45 sq meters = 766.67 LPM/sq meters. - Filter 2 is 403 LPM/0.45 sq meters = 895.56 LPM/sq meters or 21.73 GPM/sq ft which is outside values noted in the Pool Standards and the manufacturer's spec of 20 GPM/sq ft. Flow rate that was observed for each filter was 345 LPM and 403 LPM. The filter running at 403 LPM exceeds the filtration flow rate of 370 LPM. Please ensure that the flow rates for each filter are adjusted to ensure adequate turnover as well as safe pool operation.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The main drains were replaced and a new anti-entrapment plan was not submitted.Ensure new anti-entrapment plan is submitted for review
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
1 infraction
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The main drains were replaced and new antientrapment plan was not submitted.- Ensure new anti-entrapment plan is submitted for review
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Turnover 5hrs Operator confirmed that the pool was constructed in 2011. 211,000L/ (360+320L/M)- increase flow rate to meet the 4 hours turnover requirement
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- The main drains were replaced and new antientrapment plan was not submitted.- Ensure new anti-entrapment plan is submitted for review
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?