Lil Bettas Swim School - Swimming Pool
4000 - 130 Sierra Springs Drive SE Airdrie AB T4B 3G6 · Aquatic Facility
15 inspections
- Demand Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample submitted on Dec. 9 was not processed due to date of collection not indicated on the sample form.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH measurement taken was 7.8. Please ensure this is corrected.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH measurement taken was 7.8. Please ensure this is corrected.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. August 12, 2025 water sample was present for total coliforms.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Monitoring Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. Re-sample submitted on November 11 came back with a Heterotrophic plate count of <10.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- 1. Pseudomonas isolated in November 5, 2024 water sample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- 1. Water sample collected on November 5, 2024 had a Heterotrophic plate count of >57,000 CFU/mL.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Sample collected August 27, 2024, came back unsatisfactory due to the presence of Total Coliform Bacteria. Please treat and submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Sample collected August 27, 2024, came back unsatisfactory due to a high Heterotrophic Plate Count of >57,000 CFU/mL.Please treat and submit a resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Demand Inspection
1 infraction
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Zep (ammonia based cleaner) and Laundry bleach were stored in the same area to be used for cleaning the deck. Ensure that these cleaning products are stored separately so that they are not combined or used in unison for cleaning. Bleach for cleaning the deck must be plain concentrated bleach.
- 12. Are the general safety devices and physical conditions in this pool providing a safe environment (Critical)?
- Demand Inspection
2 infractions
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- March 19/2024 water sample had Pseudomonas isolated. Treat water to remove contamination and submit a resample.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- March 19/2024 water sample had a plate count of over 57,000 CFU/ml. Treat water to remove contamination and submit a resample.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The pool water is maintained at a temperature above 30C, and water samples are not being analyzed for Pseudomonas. Ensure that water sampling requisition form is being filled out accurately to account for the pool temperature.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The Free Available Chlorine (FAC) level was measured to be 1.57 ppm.Increase the FAC level or lower the water temperature to below 30C. If the pool is to be maintained at temperature of greater than 30C, ensure that the FAC is maintained at least 2.0 ppm.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
0 infractions
- Demand Inspection
0 infractions