Skip to content
Loading map…

Mary's Electrolysis Studio Inc.

110 - 815 8 Avenue SW Calgary AB T2P 3P2 · Personal Services

Inspection summary

Mary's Electrolysis Studio Inc. has been inspected 5 times by Alberta Health Services (Environmental Public Health) since January 16, 2024. The most recent inspection, on March 31, 2026, found no infractions.

3 of 5 inspections on record found no infractions at all. In the past 12 months there were 3 inspections with 1 infraction recorded. All recorded findings relate to upkeep, equipment or paperwork rather than direct infection-control risks to clients.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for clients. In personal service settings like salons, spas and tattoo studios, higher-risk findings are the ones that could spread infection from one client to the next, through broken skin, blood or instruments that were not properly cleaned and sterilized.

  • Equipment and utensilsLower risk

    Instruments, chairs, tables and footbaths must be made of materials that can be cleaned, kept in good repair and stored so they stay clean. Single-use items such as nail files, buffers, razors and needles must be thrown away after each client.

    Recorded once on March 27, 2026. For example: Is reusable equipment disinfected properly?

  • Permits, records and postingLower risk

    Operating permits, client records, sterilization logs and required signage. Client records matter because they let health officials contact people if an infection is linked to the business.

    Recorded once on January 16, 2024. For example: Are facility-specific written procedures established to adequately describe safe and sanitary practices?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

5 inspections

  1. Risk Management Inspection

    0 infractions

  2. Monitoring Inspection

    1 infraction

    • 20. Is reusable equipment disinfected properly?
      • 1. The steps for reprocessing semi-critical instruments are not correctly followed. - Wash tools with soap and water, rinse, thoroughly dry prior to fully submerging in undiluted high-level disinfectants for the required contact time provided by the manufacturer. Rinse with water afterwards and store in a clean/dry location.Ensure that all semi-critical instruments are reprocessed following proper procedures to achieve adequate disinfection and prevent potential risk of infection transmission.2. A bottle of CS20 and a bottle of PREempt RTU were expired. No unexpired bottles were available onsite to replace at the time of inspection.- Please discard and obtain unexpired ones.Ensure that only unexpired products are in use according to manufacturer's instructions.
  3. Demand Inspection

    0 infractions

  4. Demand Inspection

    0 infractions

  5. Monitoring Inspection

    1 infraction

    • 03. Are facility-specific written procedures established to adequately describe safe and sanitary practices?
      • Written procedures for invasive service were not complete.-Fill out template and submit for review

Nearby inspected facilities