  1. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC levels were elevated at more than 2,730 CFU.HPC (Heterotrophic Plate Count) indicate potential disinfection or treatment failures, as pool water can change rapidly.Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water, resample
  2. Monitoring Inspection

    0 infractions

  3. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC levels were elevated at more than 57,000 CFU.HPC (Heterotrophic Plate Count) indicate potential disinfection or treatment failures, as pool water can change rapidly.Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water, resample
  4. Monitoring Inspection

    0 infractions

  5. Monitoring Inspection

    0 infractions

  6. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC levels were elevated at 2,280 CFU.HPC (Heterotrophic Plate Count) indicate potential disinfection or treatment failures, as pool water can change rapidly.Increase Free Available Chlorine (FAC) level to 10 ppm and maintain pH at or near 7.2.Run the water through the circulation system for at least one turnover. Balance the water, resample
  7. Risk Management Inspection

    0 infractions

  8. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Sample collected on July 23, 2024:TC PRESENTHPC 520 CFU/mL
    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on July 23, 2024:TC PRESENTHPC 520 CFU/mL
  9. Risk Management Inspection

    0 infractions

  10. Demand Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on March 18, 2024: TC ABSENTHPC 2590 CFU/mLThe operator was informed of treatment procedure.
    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Water was dripping from the ceiling. Please maintain humidify 50-60%.
  11. Monitoring Inspection

    1 infraction

    • 10. Are general nuisance conditions, other than those noted in other violations, being prevented at this pool (Non-Critical)?
      • Water was dripping from the ceiling. Please maintain humidify 50-60%.
  12. Risk Management Inspection

    0 infractions

  13. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on January 02: HPC = 470 CFU/mLTC ABSENT
  14. Risk Management Inspection

    0 infractions

  15. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on Dec 11:HPC = 450 CFU/mLTC ABSENT
  16. Risk Management Inspection

    0 infractions

  17. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample collected on Nov 27HPC=3260 CFU/mLTC absentTreatment procedure was sent to the manager by email. Please follow the procedure and resample.
  18. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC=540 CFU/mLTC absent
  19. Monitoring Inspection

    0 infractions

  20. Risk Management Inspection

    0 infractions

  21. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC > 57000 CFU/mLTC absent
  22. Risk Management Inspection

    0 infractions