Mirage Salon & Spa
7A-1125 Bloor St Mississauga ON L4Y 2N4 · Manicure / Pedicure
2 inspections
- Required
1 infraction
- Did operator discard single use equipment immediately after each use?
- Discard single use equipment immediately after use.
- Did operator discard single use equipment immediately after each use?
- Required
3 infractions
- Did operator maintain setting and work surfaces in a safe and sanitary condition?
- Remove equipment and supplies no longer used/required for the operation of the setting.
- Did operator properly clean reusable equipment?
- Clean reusable equipment after use on a client to prevent disease transmission.
- Provide and use cleaning supplies (e.g., scrub brush, detergent) and ensure they are easily accessible.
- Disassemble reusable equipment prior to cleaning.
- Clean reusable equipment with a scrub brush and detergent.
- Did operator properly disinfect equipment and surfaces?
- Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
- Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
- Pedicure basin without recirculation: Clean and intermediate-level disinfect pipe-less basin and all removable parts (if applicable) after every use. First clean with detergent, water and a scrub brush. Rinse with clean water and intermediate level disinfect. Rinse again with clean water.
- Pedicure basin with recirculation: Clean and intermediate-level disinfect the basin after every use. First clean the basin and all removable parts with detergent, water and a scrub brush. Fill the basin with water above the jets, add detergent and recirculate for approximately 5 minutes. Drain, fill with water and recirculate again to rinse. Drain, fill with water and add an intermediate-level disinfectant such as 20 ml (4 tsp) of 5.25% bleach with 1 L (4 cups) of cold water (e.g., 20 L foot spa would require 400 ml of bleach). Recirculate the disinfectant for 10 minutes. Drain, fill with water and recirculate again to rinse the disinfectant. (Show More)
- Pedicure basin filter/screen (e.g., magnet screens): Remove, dismantle, clean then intermediate level disinfect after every use.
- Did operator maintain setting and work surfaces in a safe and sanitary condition?