Mississauga Flea Market - Beauty Bliss by Sana

A135-3092 Mavis Rd Mississauga ON L5C 1T8 · Ear Piercing

1 inspection

  1. Required

    2 infractions

    • Did operator discard single use equipment immediately after each use?
      • Discard single use equipment immediately after use.
      • Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
    • Did operator properly disinfect equipment and surfaces?
      • Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
      • High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
      • High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.