Skip to content
Loading map…

Moderm Laser and Aesthetics

107 - 11420 27 Street SE Calgary AB T2Z 3R6 · Personal Services

5 inspections

  1. Risk Management Inspection

    0 infractions

  2. Risk Management Inspection

    1 infraction

    • 20. Is reusable equipment disinfected properly?
      • 1. Cleaning cycle has not been conducted for the hydrafacial machine. Please review the manufacturer's instruction for use and follow its cleaning instruction, as well as cleaning and emptying of the waste container.
  3. Risk Management Inspection

    2 infractions

    • 20. Is reusable equipment disinfected properly?
      • 1. Cavicide solution expired Jan. 2023; CS20 expired Nov. 2023; Caviwipe expired Aug 2024. Please do not use expired disinfectant.2. Cleaning cycle has not been conducted for the hydrafacial machine. Please review the manufacturer's instruction for use and follow its cleaning instruction, as well as cleaning and emptying of the waste container.3. The alcohol pad used for disinfecting the laser applicator does not have a Drug Identification Number and not designed as a disinfectant. Please obtain appropriate disinfectant to disinfect the laser device.
    • 24. Are waste sharps disposed of properly?
      • Several filled sharps containers have not been discarded and one was overfilled. Please properly dispose these and do not overfill them.
  4. Monitoring Inspection

    3 infractions

    • 08. Is hand hygiene performed by the personal services worker when required, in a proper manner and are provisions available to perform hand hygiene?
      • Missing paper towel in dispenser for the hand washing basin in the permanent make up room. Hand soap was available.
    • 20. Is reusable equipment disinfected properly?
      • 1. Cavicide solution expired Jan. 2023; CS20 expired Nov. 2023; Caviwipe expired Aug 2024. Please do not use expired disinfectant.2. Cleaning cycle has not been conducted for the hydrafacial machine. Please review the manufacturer's instruction for use and follow its cleaning instruction, as well as cleaning and emptying of the waste container.3. The alcohol pad used for disinfecting the laser applicator does not have a Drug Identification Number and not designed as a disinfectant. Please obtain appropriate disinfectant to disinfect the laser device.
    • 24. Are waste sharps disposed of properly?
      • Several filled sharps containers have not been discarded and one was overfilled. Please properly dispose these and do not overfill them.
  5. Monitoring Inspection

    0 infractions