Motel 6 - Pool
810 Exeter Rd, London ON N6E 1L5 · Pool - Class B (Indoor)
13 inspections
- Required
0 infractions
- Required
0 infractions
- Required
0 infractions
- Required
0 infractions
- Required
0 infractions
- Required
0 infractions
- Required
0 infractions
- Follow-up
0 infractions
- Required
6 infractions
- Water facility and equipment maintained in a safe and sanitary condition
- Fail to ensure water facility and/or equipment maintained in a safe and sanitary manner
- All components of the pool are maintained in good working order
- Fail to maintain all components of the facility in good working order
- Pool enclosure and/or area maintained in a sanitary condition and free from hazards
- Fail to maintain deck surfaces in a sanitary condition
- Exposed piping within the pool enclosure, inside structure of the pool and inside appurtenant structures to the pool are identified
- Fail to ensure piping is identified using appropriate colour (chlorine - yellow, potable water - green)
- Fail to provide coloured bands at least 25 mm wide, in intervals not greater than 1.2 m
- Manual water testing conducted every four hours during daily use period for pools with automatic sensing devices
- Fail to manually test and record pH at least every four hours during daily use period
- Fail to manually test and record free available chlorine at least every four hours during daily use period
- Fail to manually test and record total chlorine at least every four hours during daily use period
- Fail to manually test and record total alkalinity at least every four hours during daily use period
- Fail to manually check and record water clarity at least every four hours during daily use period
- Safety equipment available and in good repair
- Fail to ensure two buoyant throwing aids with securely attached rope meeting requirements conveniently located for emergency use
- Water facility and equipment maintained in a safe and sanitary condition
- Required
0 infractions
- Required
2 infractions
- Make up water added each operating day
- Fail to ensure 15 litres per bather is added daily
- Other records
- Fail to ensure all water, gravity and suction outlet covers are inspected at least once every 30 operating days
- Fail to ensure test buttons associated with ground current leakage detecting or de-energizing devices tested monthly or according to manufacturer’s instructions, whichever is more frequent
- Fail to ensure emergency stop button at public pool tested once every 30 operating days (if applicable)
- Fail to ensure written record of each inspection is made and signed by the person who performed the inspection
- Make up water added each operating day
- Required
1 infraction
- Daily records completed and sign
- Fail to keep and record make-up water reading
- Daily records completed and sign
- Required
2 infractions
- Oxidation reduction potential (ORP) value is within required range
- Fail to ensure ORP maintained between 600 mV to 900 mV
- Other records
- Fail to ensure all water, gravity and suction outlet covers are inspected at least once every 30 operating days
- Fail to ensure test buttons associated with ground current leakage detecting or de-energizing devices tested monthly or according to manufacturer’s instructions, whichever is more frequent
- Fail to ensure emergency stop button at public pool tested once every 30 operating days (if applicable)
- Fail to ensure written record of each inspection is made and signed by the person who performed the inspection
- Oxidation reduction potential (ORP) value is within required range