Movati Athletic - Cold Plunge 1(A)
135 Albany Drive NW Edmonton AB T6V 1J6 · Aquatic Facility
Inspection summary
Movati Athletic - Cold Plunge 1(A) has been inspected 7 times by Alberta Health Services (Environmental Public Health) since April 30, 2025. The most recent inspection, on September 29, 2026, recorded 1 infraction.
2 of 7 inspections on record found no infractions at all. In the past 12 months there was 1 inspection with 1 infraction recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.
The number of infractions per inspection has stayed roughly the same over time.
What these findings mean
Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.
Pool and spa water qualityHigher risk
For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.
Recorded 7 times across 5 separate inspections, most recently on September 29, 2026. For example:
Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
Chemicals and toxic substancesHigher risk
Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.
Recorded 2 times across 2 separate inspections, most recently on October 9, 2025. For example:
Is the chemical quality of the water in this pool satisfactory (Critical)?
About this data
These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.
7 inspections
- Monitoring Inspection
1 infraction
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. With a flow rate of 12-13 GPM, filtration rate was too fast. Ideal flow rate is 1 - 9 GPM. The flow rate was decreased at the time of inspection as per request. Ensure flow rate continues to be maintained at 1 - 9 GPM.2. The water level was below the skimmer. Adjustments were made at the time of inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.64. The pH of the water in a pool must be maintained between 6.8 and 7.6. Please make necessary adjustments.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The water level was below the skimmer during the previous site visit and was now too high. Adjustments are required.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The flow rate was 11 GPM which is too fast. Ideal flow rate is 1 - 9 GPM. The flow rate was decreased to 9 GPM at the time of inspection as per request.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- 1. The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 7.61 and controller pH readings are 7.20 which is a difference 0.41. A difference of +/- 0.2 is considered acceptable. Please take corrective actions as deemed necessary.2. The water level was below the skimmer. Adjustments are required.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 8.01 and controller pH readings are 7.43 which is a difference 0.53. A difference of +/- 0.2 is considered acceptable.The flow rate is 18 GPM which is too fast. Ideal flow rate is 1 - 9 GPM.The filtration rate is 0.72 GPM/sq.ft. which exceeds manufacturer's specifications. A maximum filtration rate of 0.375 GPM/sq.ft. is permitted.Automated controller adjustments were made at the time of inspection.Skimmer was adjusted at the time of inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 7.22 and controller pH readings are 6.85 which is a difference of 0.37. A difference of +/- 0.2 is considered acceptable.The flow rate is 20 GPM which is too fast. Ideal flow rate is 1-9 GPM.The filtration rate is 0.80 GPM/sq.ft. which exceeds manufacturer's specifications. A maximum filtration rate of 0.375 GPM/sq.ft. is permitted as specified by the manufacturer.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Risk Management Inspection
0 infractions
- Initial Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH level is 8.01, which is too high. Adjustments were made at the time of inspection.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 8.01 and controller pH readings are 7.43 which is a difference 0.53. A difference of +/- 0.2 is considered acceptable.The flow rate is 18 GPM which is too fast. Ideal flow rate is 1 - 9 GPM.The filtration rate is 0.72 GPM/sq.ft. which exceeds manufacturer's specifications. A maximum filtration rate of 0.375 GPM/sq.ft. is permitted.Automated controller adjustments were made at the time of inspection.Skimmer was adjusted at the time of inspection.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?