Movati Athletic - Cold Tub
135 Albany Drive NW Edmonton AB T6V 1J6 · Aquatic Facility
11 inspections
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- The microbiological water sample result collected on 09/12/2025 [ID: 25EN-343E00746] was unsatisfactory: total coliforms present. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- that the microbiological water sample result collected on 12/11/2025 was unsatisfactory: 220 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
4 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.67. The pH of the water in a pool must be maintained between 6.8 and 7.6. Please make necessary adjustments.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.72. The pH of the water in a pool must be maintained between 6.8 and 7.6. Please make necessary adjustments.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 7.67 and controller pH readings are 7.30 which is a difference 0.37. A difference of +/- 0.2 is considered acceptable. Please take corrective actions as deemed necessary.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 7.72 and controller pH readings are 7.30 which is a difference 0.42. A difference of +/- 0.2 is considered acceptable. Please take corrective actions as deemed necessary.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Monitoring Inspection
2 infractions
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- The pH was 7.67. The pH of the water in a pool must be maintained between 6.8 and 7.6. Please make necessary adjustments.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- The automated chemical feeding and monitoring equipment readings are not consistent with manual tests. Manual pH levels are 7.67 and controller pH readings are 7.30 which is a difference 0.37. A difference of +/- 0.2 is considered acceptable. Please take corrective actions as deemed necessary.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- The microbiological water sample result collected on 05/08/2025 [ID: 25EN-217E00161] was unsatisfactory: HPC 130 CFU/mL. Take all necessary action to ensure microbiologically safe water. Submit a new microbiological water sample at your earliest convenience once the water chemistry is balanced.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Initial Inspection
0 infractions
- Demand Inspection
2 infractions
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?
- Floating weirs are not installed at time of inspection. Pool contractor confirmed they were onsite and would install now that the pools are circulating.
- 17. Does the pool have adequate written policies, plans and posted rules and safety information to ensure that the pool is operating in a safe manner?
- Complete anti-entrapment compliance plan still needs to be provided to this office.
- 07. Are the filtration, circulation and disinfection systems used to maintain water quality working properly (Non-Critical)?