Nails For You
8-556 Arbutus Way Mississauga ON L5B 3M8 · Manicure / Pedicure
3 inspections
- Required
2 infractions
- Did operator discard single use equipment immediately after each use?
- Ensure that all equipment designed for single use or made of a material that does not withstand cleaning and disinfection or sterilization is discarded immediately after use (e.g., nail files, buffer blocks, gloves, sponges, applicator sticks, ear piercing adapters).
- Did operator maintain reusable equipment in good repair and sanitary condition?
- Ensure all equipment is maintained in good repair and in a sanitary condition.
- Did operator discard single use equipment immediately after each use?
- Required
1 infraction
- Did operator properly disinfect equipment and surfaces?
- Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
- Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
- High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
- High-level disinfect equipment such as grater-style foot files, comedone extractor with loops on both ends, and diamond microdermabrasion tips.
- Did operator properly disinfect equipment and surfaces?
- Required
1 infraction
- Did operator properly disinfect equipment and surfaces?
- Do not spray or wipe equipment and surfaces with 70-90% alcohol. Alcohol evaporates quickly and will not reach the 10 minute contact time. Equipment must be fully immersed in the alcohol.
- Fully immerse equipment in 70-90% alcohol for 10 minutes and then discard the alcohol. Do not re-use the alcohol. When soaking equipment, new alcohol must be used for each batch of equipment.
- High-level disinfectant: Mix 125 ml (½ cup) of 5.25% bleach with 1 L (4 cups) of cold water. Ensure the disinfectant remains wet on the equipment for 10 minutes. Rinse with water and air dry. Prepare a new bleach and water solution daily.
- High-level disinfect equipment that holds, manipulates or contacts sterile items (e.g., needle probe holder, microblading handle, microneedle roller handle, micropigmentation reusable needle sleeve and front casing).
- Did operator properly disinfect equipment and surfaces?