Nicholas Sheran Leisure Centre - Lap Pool has been inspected 26 times by Alberta Health Services (Environmental Public Health) since December 11, 2023. The most recent inspection, on April 18, 2026, recorded 1 infraction.

8 of 26 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 6 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The number of infractions per inspection has stayed roughly the same over time.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 15 times across 15 separate inspections, most recently on October 27, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 6 times across 6 separate inspections, most recently on April 18, 2026. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

26 inspections

  1. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 46 ppm at the time of the inspection. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be addressed at the next routine inspection.
  2. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 46 ppm at the time of the inspection. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be addressed at the next routine inspection.
  3. Demand Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC PositiveHPC<10Operator advised that he will check chlorine and ensure the levels are up.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 46 ppm at the time of the inspection. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be addressed at the next routine inspection.
  4. Monitoring Inspection

    2 infractions

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • TC PositiveHPC<10Operator advised that he will check chlorine and ensure the levels are up.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 40 ppm at the time of the inspection. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be addressed at the next routine inspection.
  5. Monitoring Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 46 ppm at the time of the inspection. Please ensure that the alkalinity is maintained between 60-180 ppm at all times. This will be addressed at the next routine inspection.
  6. Risk Management Inspection

    0 infractions

  7. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • An HPC of 150 CFU/mL was isolated in the sample collected March 24. Please address the HPC in the pool and submit a resample once complete.
  8. Risk Management Inspection

    0 infractions

  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The HPC requirement (100 cfu/ml) was exceeded. The level indicated in the sample from the past week was 1,900 cfu/ml.
  10. Monitoring Inspection

    2 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • The HPC requirement (100 cfu/ml) was exceeded. The level indicated in the sample from the past week (sampled Oct 9) was 1,900 cfu/ml.
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The alkalinity was measured to be 35 ppm. Please ensure the alkalinity is maintained between 60-180 ppm at all times.
  11. Risk Management Inspection

    0 infractions

  12. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Sample Result taken Tuesday, June 4, 2024.HPC: 430 CFU/mLChlorine was already increased and filters backwashed just after the sample was taken.
  13. Risk Management Inspection

    0 infractions

  14. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • An HPC of 130 CFU/mL was isolated in the March 21 sample. Please address the HPC in the pool and submit a resample once complete.
  15. Risk Management Inspection

    0 infractions

  16. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • An HPC of 260 CFU/mL was isolated in the sample collected February 26. An HPC of 210 CFU/mL was isolated in the sample collected February 22. HPC 860 CFU/mL in sample collected February 15.Please address the HPC in the main pool and submit a resample once complete.
  17. Risk Management Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • An HPC of 210 CFU/mL was isolated in the sample collected February 22. HPC 860 CFU/mL in sample collected February 15.Please address the HPC in the main pool and submit a resample once complete.
  18. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • An HPC of 210 CFU/mL was isolated in the sample collected February 22. HPC 860 CFU/mL in sample collected February 15.Please address the HPC in the main pool and submit a resample once complete.
  19. Monitoring Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 860 CFU/mL in sample collected February 15.
  20. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 860 CFU/ml
  21. Risk Management Inspection

    0 infractions

  22. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Pool results with high HPC 430CFU/ml
  23. Risk Management Inspection

    0 infractions

  24. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • HPC 250
  25. Risk Management Inspection

    0 infractions

  26. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Total coliforms were present in the sample collected December 7. Please shock the pool and submit a resample.