Nita Lake Lodge - West End aka Lakeside

2131 Lake Placid Rd, Whistler BC V8E 0B2 · Hot Tub

Inspection summary

Nita Lake Lodge - West End aka Lakeside has been inspected 29 times by Vancouver Coastal Health since June 12, 2015. The most recent inspection, on June 20, 2025, recorded 2 infractions.

5 of 29 inspections on record found no infractions at all. No inspections are on record from the past 12 months. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 59 times across 23 separate inspections, most recently on June 20, 2025. For example: The pool alkalinity is properly maintained

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on December 19, 2017. For example: Chemicals are stored in a safe manner and location

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 12 times across 12 separate inspections, most recently on June 20, 2025. For example: Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications

  • Other findingsLower risk

    Findings that do not fit the categories above, such as follow-ups that confirm an earlier violation was corrected, or requirements specific to this type of facility.

    Recorded 4 times across 4 separate inspections, most recently on November 27, 2019. For example: The heat trace system is functioning properly and keeps deck clear of snow and ice.

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

29 inspections

  1. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Total Alkalinity is too high and is not at a level to maintain chemically balanced pool water.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
  2. Routine

    1 infraction

    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Floating weir and/or skimmer basket is missing from the skimmer box.
  3. Routine Follow-up

    1 infraction

    • Pool water velocity and recirculation rate is properly maintained
  4. Routine

    3 infractions

    • The pool disinfectant is properly maintained
      • Free available chlorine is less than 1.5 ppm at temperature above 30°C.
    • Pool water velocity and recirculation rate is properly maintained
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  5. Routine

    3 infractions

    • Pool water velocity and recirculation rate is properly maintained
      • The pool water is not being recirculated at the design flow rate.
    • The operator maintains the pool in good repair.
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
  6. Routine Follow-up

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool water velocity and recirculation rate is properly maintained
  7. Routine

    2 infractions

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
    • Pool water velocity and recirculation rate is properly maintained
      • The pool water is not being recirculated at the design flow rate.
  8. Routine Follow-up

    1 infraction

    • Pool water velocity and recirculation rate is properly maintained
  9. Routine Follow-up

    3 infractions

    • Pool water velocity and recirculation rate is properly maintained
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
    • Daily pool records are adequately maintained and available on site
  10. Routine

    4 infractions

    • The pool disinfectant is properly maintained
      • Chlorine Cyanurate is less than 2.0 ppm at temperature above 30°C
    • Pool water velocity and recirculation rate is properly maintained
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  11. Routine Follow-up

    2 infractions

    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  12. Routine Follow-up

    3 infractions

    • The pool alkalinity is properly maintained
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  13. Request

    0 infractions

  14. Routine

    4 infractions

    • The pool disinfectant is properly maintained
    • The pool alkalinity is properly maintained
    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Floating weir and/or skimmer basket is missing from the skimmer box.
  15. Routine Follow-up

    0 infractions

  16. Routine

    3 infractions

    • The pool alkalinity is properly maintained
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • The heat trace system is functioning properly and keeps deck clear of snow and ice.
  17. Routine Follow-up

    0 infractions

  18. Routine

    3 infractions

    • The pool pH level is properly maintained
    • The pool alkalinity is properly maintained
    • The pool cyanuric acid stabilizer level is properly maintained
  19. Routine Follow-up

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  20. Routine

    5 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool disinfectant is properly maintained
      • Free available chlorine is in excess of 10 ppm.
    • The pool cyanuric acid stabilizer level is properly maintained
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Staff have inadequate knowledge or training for pool operation.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
  21. Routine Follow-up

    0 infractions

  22. Routine

    3 infractions

    • The pool disinfectant is properly maintained
      • Chlorine Cyanurate is less than 2.0 ppm at temperature > 30°C
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Employees are not adequately trained according to the Pool Safety Plan.
  23. Routine

    6 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool cyanuric acid stabilizer level is properly maintained
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Staff have inadequate knowledge or training for pool operation.
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
      • Floating weir or skimmer basket is missing from the skimmer box.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Flow meter is not functioning correctly
    • Chemicals are stored in a safe manner and location
      • Incompatible chemicals (Strong acids, strong bases, chlorine and organic chlorines) are not adequately separated.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
      • Pool safety plan is not adequately developed.
  24. Routine

    3 infractions

    • The pool disinfectant is properly maintained
      • Chlorine Cyanurate is less than 2.0 ppm at temperature > 30°C
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Staff have inadequate knowledge or training for pool operation.
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  25. Routine

    7 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool disinfectant is properly maintained
      • Chlorine Cyanurate is less than 2.0 ppm at temperature > 30°C
    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool cyanuric acid stabilizer level is properly maintained
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Pool aprons, walkways and floors do not have a surface that is slip-resistant when wet.
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
      • Floating weir or skimmer basket is missing from the skimmer box.
    • An operator of a pool has prepared, maintains, and follows a written pool safety plan to ensure the health and safety of pool patrons
  26. Routine

    2 infractions

    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
  27. Routine Follow-up

    0 infractions

  28. Routine

    4 infractions

    • The pool combined chlorine level is properly maintained
      • The pool combined chlorine level is greater than or equal to 1.0 ppm
    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • The pool is regularly maintained and kept in good repair by an appropriately trained person
      • Nose of any step or ledge in the pool is not marked in a contrasting colour.
      • Floating weir or skimmer basket is missing from the skimmer box.
    • The pool does not present any suction or entrapment hazards to pool patrons
      • A main drain cover is broken or is missing.
  29. Routine

    9 infractions

    • Construction of the pool is in accordance with approved plans and specifications.
    • The pool pH level is properly maintained
    • The pool alkalinity is properly maintained
    • The pool disinfectant is properly maintained
    • The pool cyanuric acid stabilizer level is properly maintained
    • The hot tub enclosure has a clock and instructions for safe use of the hot tub, in clear view
      • Clock prominently displaying the time is not present or in clear view
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
    • Chemicals are stored in a safe manner and location
      • Liquid acid and liquid chlorine containers stored in the same room are not adequately protected from each other through proper barriers.
    • Daily pool records are adequately maintained and available on site