Skip to content
Loading map…

Oakmont Plaza - Outdoor Pool

5926 Tisdall St, Vancouver BC V5Z 3N2 · Pool

Inspection summary

Oakmont Plaza - Outdoor Pool has been inspected 18 times by Vancouver Coastal Health since July 7, 2015. The most recent inspection, on September 18, 2026, found no infractions.

4 of 18 inspections on record found no infractions at all. In the past 12 months there were 4 inspections with 3 infractions recorded. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

Recent inspections have recorded more infractions than earlier ones, so it is worth reading the latest reports closely.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 28 times across 14 separate inspections, most recently on September 9, 2026. For example: The pool cyanuric acid stabilizer level is properly maintained

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 2 times across 2 separate inspections, most recently on June 3, 2025. For example: Chemicals are stored in a safe manner and location

  • Equipment and utensilsLower risk

    Pumps, filters, chemical feeders and safety equipment such as lifebuoys, reaching poles and first-aid kits must be present and working. Missing safety equipment can matter a great deal in an emergency.

    Recorded 4 times across 4 separate inspections, most recently on September 9, 2026. For example: Adequate safety equipment is provided

  • Building, plumbing and upkeepLower risk

    Decks, ladders, fencing, drains, washrooms and signage must be in good repair. Damaged drain covers or broken fencing can be real safety hazards, while most other upkeep issues are lower risk.

    Recorded once on July 16, 2024. For example: Construction or alterations have occurred with a valid construction permit or waiver.

About this data

These results come from Vancouver Coastal Health, which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

18 inspections

  1. Routine Follow-up

    0 infractions

  2. Routine

    2 infractions

    • The pool cyanuric acid stabilizer level is properly maintained
    • Adequate safety equipment is provided
  3. Routine Follow-up

    0 infractions

  4. Routine

    1 infraction

    • The pool pH level is properly maintained
  5. Routine

    3 infractions

    • Chemicals are stored in a safe manner and location
      • Chemicals are stored directly on the floor.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • Skimmer does not adequately draw surface water from the pool.
    • Drinking water is reasonably accessible by pool patrons
      • Drinking water is not reasonably accessible by pool patrons
  6. Routine

    5 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • The pool alkalinity is properly maintained
      • Total Alkalinity is too low and is not at a level to maintain chemically balanced pool water.
    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • The operator maintains the pool in good repair.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • The pool chemical test kit is absent/not in good condition and/or cannot produce accurate readings for required chemical parameters.
  7. Routine

    3 infractions

    • Construction or alterations have occurred with a valid construction permit or waiver.
      • A main drain cover and/or sump or suction fitting has been changed without authorization.
    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  8. Routine Follow-up

    0 infractions

  9. Routine

    8 infractions

    • The pool disinfectant is properly maintained
      • Free available chlorine is less than 0.5 ppm at temperature of 30°C or below.
    • Chemicals are stored in a safe manner and location
      • Chemicals are stored directly on the floor.
    • Pool rules are posted prominently within the pool enclosure
    • The pool is clean, clear of obstructions, and adequately supplied
      • The pool is not kept clean and clear of obstructions.
      • Soap and/or single-use hand towels are not available in the dispensers.
    • The operator maintains the pool in good repair.
      • Handrails at steps, ladders and diving boards are not secure.
    • Pool equipment is regularly tested for safety and maintained in accordance with the manufacturers' specifications
      • The pool chemical test kit is absent/not in good condition and/or cannot produce accurate readings for required chemical parameters.
      • Flow meter is not functioning correctly
    • Drinking water is reasonably accessible by pool patrons
      • Drinking water is not reasonably accessible by pool patrons
    • Daily pool records are adequately maintained and available on site
      • Results of water testing are inadequately recorded.
  10. Routine

    2 infractions

    • Pool rules are posted prominently within the pool enclosure
      • Safety rules sign missing, incomplete, or not clearly visible to the public
    • Drinking water is reasonably accessible by pool patrons
      • Drinking water is not reasonably accessible by pool patrons
  11. Routine

    2 infractions

    • The pool pH level is properly maintained
      • pH level is not within 7.2 and 7.8
    • Daily pool records are adequately maintained and available on site
      • Results of daily water testing are inadequately recorded: Free Available Chlorine, Combined Available Chlorine and pH are tested and recorded at least twice daily; Alkalinity and Cyanuric Acid are tested and recorded at least weekly.
  12. Routine

    1 infraction

    • The pool is clean, clear of obstructions, and adequately supplied
  13. Routine

    0 infractions

  14. Routine

    1 infraction

    • The pool alkalinity is properly maintained
      • Alkalinity is not between 80 ppm and 120 ppm
  15. Routine

    1 infraction

    • Pool rules are posted prominently within the pool enclosure
      • Safety rules sign missing, incomplete, or not clearly visible to the public
  16. Routine

    2 infractions

    • The pool pH level is properly maintained
    • Pool water velocity and recirculation rate is properly maintained
  17. Routine Follow-up

    1 infraction

    • Pool water velocity and recirculation rate is properly maintained
  18. Routine

    3 infractions

    • The pool cyanuric acid stabilizer level is properly maintained
      • The cyanuric acid stabilizer level is greater than 80 ppm
    • Pool water velocity and recirculation rate is properly maintained
    • Daily pool records are adequately maintained and available on site
      • Results of daily water testing is inadequately recorded: Free Available Chlorine, Combined Available Chlorine and pH is tested and recorded at least twice daily; Alkalinity and Cyanuric Acid is tested and recorded at least weekly.

Nearby inspected facilities

Own this business? Add a badge to your website