Offline Wellness Spa - Cold Plunge 2
1214 11 Avenue SW Calgary AB T3C 0M4 · Aquatic Facility
11 inspections
- Monitoring Inspection
0 infractions
- Demand Inspection
0 infractions
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Water sample (25ES-210E00676) collected on July 29th, 2025, came back unsatisfactory as Total Coliforms were present in the sample. Please treat the water and resample as soon as possible.
- 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
- Risk Management Inspection
0 infractions
- Risk Management Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was tested to be above 1.94ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Initial Inspection
1 infraction
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was tested to be above 3.48ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
3 infractions
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on April 21st, 2025, was rejected by the lab as there was no identification number on the bottle. Please submit another sample for the cold plunge.
- 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
- pH was tested to be over 8.4 (Poollab 2.0 has a max testing range of 8.4 and test was reading OR indicating the result was over the testing range). pH must be kept between 6.8-7.6 (Recommend 7.2)
- 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
- The combined chlorine was tested to be 1.86ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on April 21st, 2025, was rejected by the lab as there was no identification number on the bottle. Please submit another sample for the cold plunge.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Risk Management Inspection
0 infractions
- Demand Inspection
1 infraction
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
- Water sample collected on March 25th, 2025, came back unsatisfactory as an HPC count of 250CFU/ml was determined. Please re-sample the cold plunge - 2.
- 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?