Offline Wellness Spa - Cold Plunge 2

1214 11 Avenue SW Calgary AB T3C 0M4 · Aquatic Facility

Inspection summary

Offline Wellness Spa - Cold Plunge 2 has been inspected 11 times by Alberta Health Services (Environmental Public Health) since March 28, 2025. The most recent inspection, on October 2, 2025, found no infractions.

5 of 11 inspections on record found no infractions at all. No inspections are on record from the past 12 months. The higher-risk findings here relate to: Pool and spa water quality and Chemicals and toxic substances.

The last 3 inspections in a row found no infractions. Recent inspections have recorded fewer infractions than earlier ones, so the record is improving.

What these findings mean

Health authorities word their findings differently, so we group them by what they mean for the people using the facility. Higher-risk findings are the ones that could directly cause illness or injury, such as water that is not properly treated.

  • Pool and spa water qualityHigher risk

    For pools, spas and splash pads, inspectors test disinfectant levels, pH and water clarity, and check safety equipment. Water that is not properly treated can spread skin, ear and stomach infections.

    Recorded 4 times across 4 separate inspections, most recently on July 31, 2025. For example: Is the bacteriological quality of the water in this pool satisfactory (Critical)?

  • Chemicals and toxic substancesHigher risk

    Pool chemicals such as chlorine and acid must be labelled, stored apart from each other and handled safely. Mixing them by mistake can release toxic gas, so storage and handling problems are treated seriously.

    Recorded 4 times across 3 separate inspections, most recently on May 7, 2025. For example: Is the chemical quality of the water in this pool satisfactory (Non-Critical)?

About this data

These results come from Alberta Health Services (Environmental Public Health), which inspects food premises and other public facilities in this area. We republish the authority's public disclosure data and refresh it regularly; the official record is the final word.

11 inspections

  1. Monitoring Inspection

    0 infractions

  2. Demand Inspection

    0 infractions

  3. Risk Management Inspection

    0 infractions

  4. Demand Inspection

    1 infraction

    • 02. Is the bacteriological quality of the water in this pool satisfactory (Critical)?
      • Water sample (25ES-210E00676) collected on July 29th, 2025, came back unsatisfactory as Total Coliforms were present in the sample. Please treat the water and resample as soon as possible.
  5. Risk Management Inspection

    0 infractions

  6. Risk Management Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was tested to be above 1.94ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
  7. Initial Inspection

    1 infraction

    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was tested to be above 3.48ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
  8. Demand Inspection

    3 infractions

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on April 21st, 2025, was rejected by the lab as there was no identification number on the bottle. Please submit another sample for the cold plunge.
    • 04. Is the chemical quality of the water in this pool satisfactory (Critical)?
      • pH was tested to be over 8.4 (Poollab 2.0 has a max testing range of 8.4 and test was reading OR indicating the result was over the testing range). pH must be kept between 6.8-7.6 (Recommend 7.2)
    • 05. Is the chemical quality of the water in this pool satisfactory (Non-Critical)?
      • The combined chlorine was tested to be 1.86ppm.Please keep combined chlorine levels as low as possible to provide maximum comfort to batters. Dilution of the cold plunges is the recommended method for reducing the combined chlorines.
  9. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on April 21st, 2025, was rejected by the lab as there was no identification number on the bottle. Please submit another sample for the cold plunge.
  10. Risk Management Inspection

    0 infractions

  11. Demand Inspection

    1 infraction

    • 03. Is the bacteriological quality of the water in this pool satisfactory (Non-Critical)?
      • Water sample collected on March 25th, 2025, came back unsatisfactory as an HPC count of 250CFU/ml was determined. Please re-sample the cold plunge - 2.